Unlabelled: Obstructive sleep apnea is a common chronic condition typically treated with positive airway pressure. However, many patients have difficulty with adherence to this therapy, and for some, implantation of a hypoglossal nerve stimulator has become an option. Although device implantation is generally well-tolerated, a minority of patients will experience serious adverse events. Here we report the unusual complication of the sensor lead migrating to the costophrenic angle and invading the pleural space. Nine months after original implantation, the sensor lead malfunctioned and was found to be displaced. Initial explantation and reimplantation of a new device resulted in the inability to find a portion of the lead. Reimaging showed the missing lead at the costophrenic angle, and the patient underwent thoracoscopic removal. He resumed therapy with the new device without difficulty. This case demonstrates the ability of the lead to migrate far from the implantation site, which has rarely been reported.

Citation: Rosen R, Padhya T, Daniel J, Sharma A. Video-assisted thoracoscopic surgery retrieval of a migrated unilateral hypoglossal nerve stimulator sensor lead. . 2024;20(11):1851-1855.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11530985PMC
http://dx.doi.org/10.5664/jcsm.11264DOI Listing

Publication Analysis

Top Keywords

sensor lead
16
hypoglossal nerve
12
nerve stimulator
12
video-assisted thoracoscopic
8
thoracoscopic surgery
8
surgery retrieval
8
retrieval migrated
8
migrated unilateral
8
unilateral hypoglossal
8
stimulator sensor
8

Similar Publications

Cytotoxic DNAs, methylation, histones and histones binding proteins are speculated to induce DNA sensors. Under stressed condition, the antigenic patterns, PAMPs and DAMPs, trigger the hyperactive innate response through DNA, DNA-RNA hybrids, oligonucleotides, histones and mtDNA to initiate cGAMP-STING-IFN I cascade. HSV -1&2, HIV, Varicella- Zoster virus, Polyomavirus, Cytomegalovirus, and KSHV negatively regulate the STING-MAVS-TBK-1/1KKE pathway.

View Article and Find Full Text PDF

Enhanced simultaneous voltammetric detection of lead, copper, and mercury using a MIL-101(Cr)-(COOH)@MWCNTs modified glassy carbon electrode.

Anal Chim Acta

February 2025

Chemistry Department, Faculty of Science, Ain-Shams University, Cairo, 11566, Egypt; Department of Chemistry, Faculty of Science, Galala University, New Galala City, Suez, Egypt. Electronic address:

Background: Electrochemical methods, particularly those utilizing sensors, offer distinct advantages over classical analytical methods. They are cost-effective, compatible with mass fabrication, suitable for remote sensing, and can be designed as handheld analyzers. In this context, MIL-101(Cr)-(COOH)₂@MWCNTs was utilized for the first time as a modifier for GCE for the sensitive voltammetric detection of Pb(II), Cu(II), and Hg(II).

View Article and Find Full Text PDF

Reimagining apnea monitoring in the neonatal ICU.

Curr Opin Pediatr

December 2024

Division of Neonatology, Montreal Children's Hospital, McGill University Health Center, Montreal, Quebec, Canada.

Purpose Of Review: This review outlines the prevalence and complications of apneas and intermittent hypoxemic events in preterm infants, examines current monitoring limitations in neonatal ICUs (NICUs), and explores emerging technologies addressing these challenges.

Recent Findings: New evidence from the Prematurity-Related Ventilatory Control (Pre-Vent) study, which analyzed cardiorespiratory data from 717 extremely preterm infants, exposes the varying frequency, duration, and severity of apneas, intermittent hypoxemia, bradycardias, and periodic breathing during hospitalization, and highlights the negative impact of intermittent hypoxemia on pulmonary outcomes at discharge. Although traditional monitoring methods cannot differentiate between apnea types and quantify their burden, recent advancements in sensor technologies and data integration hold promise for improving real-time detection and evaluation of apneas in the NICU.

View Article and Find Full Text PDF

This work presents an optimization of the construction, treatment, and activation of 3D-printed electrochemical sensors (E-3D). For this, was used a 2-full factorial design examining three key variables at two levels: electrode height, electrode diameter, and printing speed. Moreover, it evaluates various physical, chemical, and electrochemical methods to treat and activate the E-3D surface.

View Article and Find Full Text PDF

A Sensor for Detecting Aqueous Cu That Functions in a Just-Add-Water Format.

ACS Omega

January 2025

Department of Chemical and Biological Engineering, Northwestern University, 2145 Sheridan Road, Evanston, Illinois 60208, United States.

There is growing concern around the negative health impacts associated with contamination of drinking water by harmful chemicals. Technology that enables fast, cheap, and easy detection of ions and small molecules in drinking water is thus important for reducing the incidence of these negative health impacts. Here, we describe a sensor for detecting Cu in water that provides colorimetric results in 15 min or less and functions in a just-add-water format.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!