Automatic adjustment of cycle ergometer power output to accurately clamp heart rate.

J Sports Sci

School of Human Sciences (Exercise and Sports Science), The University of Western Australia, Perth, Western Australia, Australia.

Published: May 2024

We assessed the accuracy and inter-sessional reliability of traditional (manual) compared to automatic (AutoHR) heart rate (HR) clamping methods during submaximal intensity continuous cycling. On separate occasions, thirteen males cycled at an HR corresponding to 80% of the ventilatory threshold for 18 min. Cycling power output was adjusted using either manual or AutoHR methods, encompassing three trials per method. For the manual method, cycling power output was adjusted every 30 s by 0, 5 or 10 W at the experimenter's discretion. Conversely, AutoHR automatically adjusted power output based on the difference between target and actual HR. Participants' HR was measured at 1 Hz. Root-mean square error (RMSE) and intraclass correlation coefficients (ICC) were calculated from the difference between measured and target HR to represent accuracy and reliability of each method. The RMSE for the manual method (3.2 ± 2.6 bpm) was significantly higher compared to AutoHR (2.8 ± 2.3 bpm) ( < 0.01,  = 0.13); inter-day ICC were 0.92 and 0.89 for manual adjustment and AutoHR, respectively. Automatic methods to clamp HR are more accurate than manual approaches during submaximal intensity continuous cycling and can be easily implemented for uniform HR control in individual and group training sessions at minimal cost.

Download full-text PDF

Source
http://dx.doi.org/10.1080/02640414.2024.2369353DOI Listing

Publication Analysis

Top Keywords

power output
16
heart rate
8
cycling power
8
output adjusted
8
manual method
8
automatic adjustment
4
adjustment cycle
4
cycle ergometer
4
power
4
ergometer power
4

Similar Publications

Balancing pH and Pressure Allows Boosting Voltage and Power Density for a H-I Redox Flow Battery.

ACS Appl Energy Mater

January 2025

Department of Chemical Engineering, Delft University of Technology, Van der Maasweg 9, 2629HZ Delft, The Netherlands.

The decoupled power and energy output of a redox flow battery (RFB) offers a key advantage in long-duration energy storage, crucial for a successful energy transition. Iodide/iodine and hydrogen/water, owing to their fast reaction kinetics, benign nature, and high solubility, provide promising battery chemistry. However, H-I RFBs suffer from low open circuit potentials, iodine crossover, and their multiphase nature.

View Article and Find Full Text PDF

Large-scale and long-term wildlife research and monitoring using camera traps: a continental synthesis.

Biol Rev Camb Philos Soc

January 2025

Wildlife Observatory of Australia (WildObs), Queensland Cyber Infrastructure Foundation (QCIF), Brisbane, Queensland, 4072, Australia.

Camera traps are widely used in wildlife research and monitoring, so it is imperative to understand their strengths, limitations, and potential for increasing impact. We investigated a decade of use of wildlife cameras (2012-2022) with a case study on Australian terrestrial vertebrates using a multifaceted approach. We (i) synthesised information from a literature review; (ii) conducted an online questionnaire of 132 professionals; (iii) hosted an in-person workshop of 28 leading experts representing academia, non-governmental organisations (NGOs), and government; and (iv) mapped camera trap usage based on all sources.

View Article and Find Full Text PDF

During the Fukushima Daiichi Nuclear Power Plant (FDNPP) accident on March 11, 2011, radionuclides such as tritium were released into the environment across Japan, obscuring the natural background signal of tritium in precipitation. This anthropogenic component was rapidly washed out by precipitation according to measurements in Japan. However, the impact of the accident on the natural tritium-based estimation of water system transit times in Fukushima and other prefectures in Japan remains uncertain.

View Article and Find Full Text PDF

Tyrosine has been proposed to potentially provide ergogenic benefits to cognitive and physical performance in physiologically demanding environments. However research into its effectiveness on cognitive and physical performance during exercise in the heat has revealed mixed findings. This study examined the effects of a commonly employed dosage of tyrosine supplementation on soccer players' physical and decision-making performance, cognitive appraisal, and affective states, during prolonged high-intensity intermittent exercise in hot conditions.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!