Sensors with a small footprint and real-time detection capabilities are crucial in robotic surgery and smart wearable equipment. Reducing device footprint while maintaining its high performance is a major challenge and a significant limitation to their development. Here, we proposed a monolithic integrated micro-scale sensor, which can be used for vector force detection. This sensor combines an optical source, four photodetectors, and a hemispherical silicone elastomer component on the same sapphire-based AlGaInP wafer. The chip-scale optical coupling is achieved by employing the laser lift-off techniques and the flip-chip bonding to a processed sapphire substrate. This hemispherical structure device can detect normal and shear forces as low as 1 mN within a measurement range of 0-220 mN for normal force and 0-15 mN for shear force. After packaging, the sensor is capable of detecting forces over a broader range, with measurement capabilities extending up to 10 N for normal forces and 0.2 N for shear forces. It has an accuracy of detecting a minimum normal force of 25 mN and a minimum shear force of 20 mN. Furthermore, this sensor has been validated to have a compact footprint of approximately 1.5 mm, while maintaining high real-time response. We also demonstrate its promising potential by combining this sensor with fine surface texture perception in the fields of compact medical robot interaction and wearable devices.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11194277PMC
http://dx.doi.org/10.1038/s41378-024-00712-6DOI Listing

Publication Analysis

Top Keywords

monolithic integrated
8
vector force
8
force detection
8
footprint maintaining
8
maintaining high
8
shear forces
8
normal force
8
shear force
8
force
6
sensor
5

Similar Publications

Although the accumulation of random genetic mutations has been traditionally viewed as the main cause of cancer progression, altered mechanobiological profiles of the cells and microenvironment also play a major role as a mutation-independent element. To probe the latter, we have previously reported a microfluidic cell-culture platform with an integrated flexible actuator and its application for sequential cyclic compression of cancer cells. The platform is composed of a control microchannel in a top layer for introducing external pressure, and a polydimethylsiloxane (PDMS) membrane from which a monolithically-integrated actuator protrudes downwards into a cell-culture microchannel.

View Article and Find Full Text PDF

The integrated frequency comb generator based on Kerr parametric oscillation has led to chip-scale, gigahertz-spaced combs with new applications spanning hyperscale telecommunications, low-noise microwave synthesis, light detection and ranging, and astrophysical spectrometer calibration. Recent progress in lithium niobate (LiNbO) photonic integrated circuits (PICs) has resulted in chip-scale, electro-optic (EO) frequency combs, offering precise comb-line positioning and simple operation without relying on the formation of dissipative Kerr solitons. However, current integrated EO combs face limited spectral coverage due to the large microwave power required to drive the non-resonant capacitive electrodes and the strong intrinsic birefringence of LiNbO.

View Article and Find Full Text PDF

This study focuses on developing an affordable and cost-effective colorimetric solid-state optical sensor for target-specific naked-eye detection of Pb, offering significant potential for real-time environmental monitoring and public health applications. The indigenously developed porous polymer monolithic template, poly(lauryl methacrylate-co-ethylene glycol dimethacrylate) (poly(LMC-co-EGDMA) is infused with a chromoionophoric probe, i.e.

View Article and Find Full Text PDF

System-level modeling with temperature compensation for a CMOS-MEMS monolithic calorimetric flow sensing SoC.

Microsyst Nanoeng

January 2025

State Key Laboratory of Radio Frequency Heterogeneous Integration, Shenzhen University, 518060, Shenzhen, China.

We present a system-level model with an on-chip temperature compensation technique for a CMOS-MEMS monolithic calorimetric flow sensing SoC. The model encompasses mechanical, thermal, and electrical domains to facilitate the co-design of a MEMS sensor and CMOS interface circuits on the EDA platform. The compensation strategy is implemented on-chip with a variable temperature difference heating circuit.

View Article and Find Full Text PDF

Continuous-flow phosphate removal using Cry-Ca-COS Monolith: Insights from dynamic adsorption modeling.

Water Res X

May 2025

Integrated Science and Technology Research Center, Faculty of Technology and Environment, Prince of Songkla University, Phuket Campus, Kathu, Phuket 83120 Thailand.

This study rigorously evaluates the adsorption performance of the Cry-Ca-COS monolith for phosphate removal in a column operation mode. Characterization of the material both before and after exhaustion in a continuous flow system (column form) showed no difference compared to results from a batch system (tablet form). The XPS results indicated that the adsorption mechanism of phosphate on the Cry-Ca-COS column involved surface microprecipitation and ligand exchange (inner-sphere complexation).