Purpose: To compare the accuracy of modern intraocular lens (IOL) power calculation formulas with that of older formulas, such as SRK/T and Hoffer Q, in pediatric cataract surgery.

Methods: This retrospective study included 100 eyes of 100 children who underwent routine cataract surgery with primary IOL implantation in a bag. This study used four IOLMaster 700 integrated formulas: SRK/T, Hoffer Q, Haigis, and Barrett Universal II (BUII). In addition, the following formulas were used: EVO 2.0, Hill RBF 3.0, Hoffer QST, Kane, and PEARL DGS, which are available online.

Results: There was a statistically significant difference between SRK/T and most other formulas, except for Hoffer Q, Hoffer QST, and BUII (p < 0.05). SRK/T yielded the lowest median absolute error (MedAE) of 0.63 D. This was followed by the BUII (0.66 D), Hoffer Q, and Hoffer QST (0.68 D). SRK/T also yielded the highest percentage of cases within ± 0.50 D (43% of the cases). For patients aged 2 to 5 years, SRK/T formula yielded statistically significantly better results than all other included formulas (p < 0.05) with MedAE = 0.44 D, 58.33% and 87.50% of the cases were within ± 0.50 D and ± 1.0 D of intended refraction, respectively.

Conclusion: The SRK/T formula showed the best IOL power calculation results in pediatric cataract surgery, followed by BUII, Hoffer Q, and Hoffer QST. In children aged 2-5 years, the SRK/T formula outperformed all other formulas, followed by the BUII and Hoffer QST formulas. In children older than 5 years, there was no statistically significant difference between the different formulas (p > 0.05); Hoffer Q and SRK/T showed slightly better MedAE in this age group (5-10 years).

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11195671PMC
http://dx.doi.org/10.2147/OPTH.S468294DOI Listing

Publication Analysis

Top Keywords

hoffer qst
20
power calculation
12
pediatric cataract
12
cataract surgery
12
hoffer hoffer
12
srk/t formula
12
hoffer
11
formulas
10
srk/t
9
accuracy modern
8

Similar Publications

Intraocular lens calculation formula selection for short eyes: based on axial length and anterior chamber depth.

BMC Ophthalmol

January 2025

State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, Guangdong, China.

Purpose: To evaluate the predictive accuracy of 11 intraocular lens (IOL) calculation formulas in eyes with an axial length (AL) less than 22.00 mm.

Methods: New-generation formulas (Barrett Universal II [BUII], Emmetropia Verifying Optical [EVO] 2.

View Article and Find Full Text PDF

Purpose: To evaluate the outcomes of scleral-fixated intraocular lenses (IOLs) implanted using either Yamane technique or Gore-Tex suture fixation, in comparison to intracapsular lens fixation, and to assess the efficacy of various lens formulas in achieving predicted refractive targets.

Patients And Methods: This study included 45 eyes from 44 patients with scleral-fixated IOLs, comprising 37 Yamane eyes and 8 Gore-Tex eyes. Preoperative refractive predictions from various formulae were compared with final postoperative refraction.

View Article and Find Full Text PDF

Background: The purpose of the study was to evaluate the relationship between prediction errors (PEs) and ocular biometric variables in cataract surgery using nine intraocular lens (IOL) formulas with an explainable machine learning model.

Methods: We retrospectively analyzed the medical records of consecutive patients who underwent standard cataract surgery with a Tecnis 1-piece IOL (ZCB00) at a single center. We calculated predicted refraction using the following IOL formulas: Barrett Universal II (BUII), Cooke K6, EVO V2.

View Article and Find Full Text PDF

Accuracy of 7 Artificial Intelligence-Based Intraocular Lens Power Calculation Formulas in Extremely Long Caucasian Eyes.

Am J Ophthalmol

November 2024

Institute for Research in Ophthalmology (A.G.), Foundation for Ophthalmology Development, Poznan, Poland; Department of Ophthalmology (A.G.), University of Warmia and Mazury, Olsztyn, Poland. Electronic address:

Purpose: To compare 7 artificial intelligence (AI)-based intraocular lens (IOL) power calculation formulas in extremely long eyes.

Design: Retrospective accuracy and validity analysis.

Setting: Kyiv Clinical Ophthalmology Hospital Eye Microsurgery Center, Ukraine.

View Article and Find Full Text PDF

This retrospective study compared postoperative prediction errors of recent formulas using standard- or total keratometry (K or TK) for intraocular lens (IOL) power calculation in post-myopic LASIK patients. It included 56 eyes of 56 patients who underwent uncomplicated cataract surgery, with at least 1-month follow-up at Keio University Hospital in Tokyo or Hayashi Eye Hospital in Yokohama, Japan. Prediction errors, absolute errors, and percentage of eyes with prediction errors within ± 0.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!