A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Automated titanium fastener for surgical aortic valve replacement-preventive role for infective endocarditis? | LitMetric

Objectives: Evidence on long-term clinical outcomes considering suture-securing techniques used for surgical aortic valve replacement is still uncertain.

Methods: A total of 1405 patients who underwent surgical aortic valve replacement between January 2016 and December 2022 were included and grouped according to the suture-securing technique used (automated titanium fastener versus hand-tied knots). The occurrence of infective endocarditis during follow-up was set as the primary study end-point. As secondary study end-points, stroke, all-cause mortality and a composite outcome of either infective endocarditis, stroke, or all-cause mortality were assessed.

Results: The automated titanium fastener was used in 829 (59%) patients, whereas the hand-knot tying technique was used in 576 (41%) patients. The multivariable proportional competing risk regression analysis showed a significantly lower risk of infective endocarditis during follow-up in the automated titanium fastener group (adjusted sub-hazard ratio 0.44, 95% confidence interval 0.20-0.94, P = 0.035). The automated titanium fastener group was not associated with an increased risk of mortality or attaining the composite outcome, respectively (adjusted hazard ratio 0.81, 95% confidence interval 0.60-1.09, P = 0.169; adjusted hazard ratio 0.82, 95% confidence interval 0.63-1.07, P = 0.152). This group was not associated with an increased risk of stroke (adjusted sub-hazard ratio 0.82, 95% confidence interval 0.47-1.45, P = 0.504). Also, a significantly lower rate of early-onset infective endocarditis was observed in the automated titanium fastener group, (0.4% vs 1.4%, P = 0.032).

Conclusions: Suture-securing with an automated titanium fastener device appears to be superior compared to the hand-knot tying technique in terms of lower risk of infective endocarditis.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11211209PMC
http://dx.doi.org/10.1093/ejcts/ezae236DOI Listing

Publication Analysis

Top Keywords

automated titanium
28
titanium fastener
28
infective endocarditis
20
95% confidence
16
confidence interval
16
surgical aortic
12
aortic valve
12
fastener group
12
valve replacement
8
endocarditis follow-up
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!