A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Biomechanical Evaluation of Zygomatic Implant Versus Pterygoid Implant in Atrophic Maxilla: An In vitro Finite Element Study. | LitMetric

Background And Purpose: Dental implants are considered to be one of several treatment options that can be used to replace missing teeth. The objective of the study is to examine and compare the biomechanics of zygomatic and pterygoid implants planned on the atrophic maxilla with three different bone types.

Materials And Methods: An in vitro finite element study was conducted on a three-dimensional model of zygomatic and pterygoid implants. In a total of 24 implants, two bilateral zygomatic and pterygoid implants with two anterior dental implants were inserted in models. 150 N vertical occlusal and 300 N load on masseter and medial pterygoid were simulated on the modeled prosthesis. The data were processed with ANSYS software. The stress on and deformations of the bones and implants were observed and compared.

Results: When comparing the D4, D3, and D2 bones in subgroup I with zygomatic implants, the D2 bone was subjected to less stress compared to D3 and D4. The smallest displacement (0.125784 mm) was seen in D4 followed by the largest displacement (0.74073 mm) in D2. Similarly, when comparing the D2, D3, and D4 bone in subgroup II with pterygoid implants, the D2 bone in the atrophic maxilla received the least amount of stress from the pterygoid implants compared to D3 and D4. Furthermore, the smallest displacement (0.030934 mm) was seen in D2, and the largest (0.046319 mm) in D4.

Conclusion: Results suggest firstly, that the overall stress was better distributed in D2 bone and secondly, the pterygoid implant showed higher stress concentration than the zygomatic implant.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11189858PMC
http://dx.doi.org/10.1007/s12663-024-02128-1DOI Listing

Publication Analysis

Top Keywords

pterygoid implants
20
atrophic maxilla
12
zygomatic pterygoid
12
implants
10
zygomatic implant
8
pterygoid
8
pterygoid implant
8
vitro finite
8
finite element
8
element study
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!