Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Introduction: Intramedullary nailing is a commonly performed surgery for tibia diaphysis fractures. However, in selected cases, this procedure can get complicated with rotational malalignment if not checked carefully intra-operatively.
Case Report: A 29 year-old male sustained polytrauma and was treated with intramedullary nailing for bilateral femur and right-side tibia fractures. Postoperatively, the patient noticed extreme in-toeing suggesting an internal rotation deformity, which caused great difficulty in walking. The patient was planned for a revision surgery to correct the internal rotation deformity, 6 months after the index surgery. A minimally invasive metaphyseal osteotomy was performed, away from his fracture site by drilling multiple holes. The distal locking bolts of the interlocking nail were removed, and two K wires used to achieve the desired correction angle. After rotating the distal fragment, locking bolts were reinserted in new holes. We kept the patient on our regular follow-up till he achieved sound union at the osteotomy site, after which we allowed him unrestricted activities.
Conclusion: The presence of an intramedullary nail can hence help the surgeon in correcting such isolated rotational deformities without getting into the hassle of implant removal to achieve the same.