Objective: To explore clinical effect of single small incision with honeycomb titanium plate in treating acute acromioclavicular dislocation.
Methods: The clinical data of 40 patients with acute acromioclavicular dislocation admitted from December 2019 to December 2021 were retrospectively analyzed and divided into two groups according to different surgical methods. Among them, 20 patients were fixed with single small incision with honeycomb titanium plate (titanium plate group), including 11 males and 9 females, aged from 23 to 65 years old with an average of (47.40±12.58) years old;12 patients on the left side, 8 patients on the right side;11 patients with type Ⅲ, 3 patients with type Ⅳ, and 6 patients with type Ⅴ according to Rockwood classification. Twenty patients were fixed with clavicular hook plate (clavicular hook group), including 8 males and 12 females, aged from 24 to 65 years old with an average of (48.40±12.08) years old;12 patients on the left side, 8 patients on the right side;10 patients with type Ⅲ, 2 patients with type Ⅳ, and 8 patients with type Ⅴ according to Rockwood classification. Operative time, incision length, intraoperative blood loss, hospital stay, visual analogue scale (VAS) and Constant-Murley score of shoulder joint function were compared between two groups. Anteroposterior radiographs of the affected shoulder joint were recorded before, immediately and 6 months after surgery, and the coracoclavicular distance was measured and compared.
Results: Both groups of patients were successfully completed operation without serious complications. All patients were followed up for 6 to 15 months with an average of (11.9±4.8) months. There were no incisional infection, internal plant fracture or failure, bone tunnel fracture and other complications occurred. The incision length of titanium plate group (35.90±3.14) mm was significantly shorter than that of clavicular hook group (49.30±3.79) mm (<0.05). There were no significant difference in operative time, intraoperative blood loss and hospital stay between two groups (>0.05). At 1 and 3 months after operation, VAS of titanium plate group was lower than that of clavicular hook group (<0.05). Connstant-Murley scores in titanium plate group at 1, 3 and 6 months after operation were (86.80±1.36), (91.60±2.32) and (94.90±2.22), respectively;and in clavicular hook group were (78.45±5.47), (85.55±2.01) and (90.25±1.92), which were higher than that of clavicular hook group (<0.05). There was no significant difference in coracoclavicular distance between two groups immediately and 6 months after operation(>0.05).
Conclusion: For the treatment of acute acromioclavicular joint dislocation, single small incision combined with honeycomb titanium plate have advantages of shorter incision, fast recovery of shoulder joint function without the second operation, and has good satisfaction of patient.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.12200/j.issn.1003-0034.20230268 | DOI Listing |
Oral Maxillofac Surg
January 2025
Department of Oral and Maxillofacial Diseases, Helsinki University and Helsinki University Hospital, Helsinki, Finland.
Purpose: Preoperative virtual planning and osteosynthesis with patient-specific implants (PSIs) have become a quotidian approach to many maxillofacial elective surgery setups. When a process is well-organized, a similar approach can be harnessed to serve the needs of exact primary reconstructions, especially in midfacial trauma cases. PSI osteosynthesis of the mandible is, however, more challenging because a mirror technique of the facial sides is often unreliable due to inherent lack of symmetry, and movement of the mandible increases the risk of loosening of the osteosynthesis.
View Article and Find Full Text PDFZhongguo Gu Shang
January 2025
Department of Thoracic Surgery, Hanyang Hospital, Wuhan University of Science and Technology, Wuhan 430050, Hubei, China.
Objective: To investigate the clinical efficacy of thoracoscopic minimally invasive surgery with nickel-titanium shape memory alloy wrap bone plate versus rib periosteal internal fixation in patients with multiple rib fractures (MRF) and flail chest.
Methods: A retrospective analysis was performed on 100 patients with MRF and flail chest treated with thoracoscopic minimally invasive surgery and internal fixation with rib fracture preservation between January 2019 and December 2022, including 54 males and 46 females, aged from 20 to 65 years old, with an average age of (38.0±18.
Hua Xi Kou Qiang Yi Xue Za Zhi
February 2025
Dept. of Oral and Maxillofacial Surgery, The First Affiliated Hospital of Bengbu Medical University, Bengbu 233004, China.
Objectives: This study aims to analyze the biomechanics of three kinds of rigid internal fixation methods for condylar head fractures.
Methods: A three dimensional finite element model of the normal mandible was constructed. It was then used to prepare condylar head fracture finite element model and three kinds of rigid internal fixation finite element model (unilateral tension screw, bilateral tension screw, tension screw+titanium plate).
Langmuir
January 2025
Department of Biomaterials, Faculty of Dental Science, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582, Japan.
Titanium alloy plates are often used for fixation to bone. However, the plates often need to be removed due to infection and adverse inflammation. To avoid these problems, we immobilized copper, which has antibacterial effects and low cytotoxicity, on titanium plates by immersing the titanium in copper-tris(hydroxymethyl)aminomethane complex solutions.
View Article and Find Full Text PDFJ Vet Dent
January 2025
Department of Dentistry, Oral and Maxillo-facial Surgery, Eastcott Veterinary Referrals, Part of Linnaeus Group, Swindon, UK.
Canine acanthomatous ameloblastoma (CAA) is an invasive benign epithelial odontogenic tumour most commonly affecting the mandible of large breed dogs. To the author's knowledge, this report describes the first computer-aided design patient-specific implant (PSI) that has been placed for a critical sized bone defect in mandibular reconstruction of a dog in the UK. The aim was to restore mandibular stability using a regenerative approach combining a titanium locking plate and compression-resistant matrix infused with recombinant human bone morphogenetic protein-2 (rhBMP-2) to bridge the 85 mm mandibular defect created by a segmental mandibulectomy.