Degree of conversion of dual-cured composite luting agents: The effect of transition metal-based touch-cure activators.

J Dent

Department of Biomaterials, School of Dentistry, National and Kapodistrian University of Athens, 2 Thivon str, 11527, Goudi, Athens, Greece. Electronic address:

Published: August 2024

Purpose: The aim of the study was (a) to assess the effect of universal adhesives and tooth primers with novel touch-cure activators on the conversion of dual-cured resin composite luting agents (RLAs) polymerized under the self-curing mode, and (b) to investigate the source of the catalytic effect exerted by the activators.

Materials And Methods: The materials selected were the adhesive RLAs Panavia V5/Tooth Primer (PV5/TP5), Variolink Esthetic DC/Adhese Universal DC (VLE/ADC), and the self-adhesive RLAs GCem ONE/AE Primer (GCO/AEP), RelyX Universal/Scotchbond Universal Plus (RXU/SUP) and Panavia SA Universal/Clearfil Universal Bond Quick (PSU/CUQ), the later serving as a control with an aryl-sulfinate activator. Coronal dentin specimens were prepared (n = 5/material), treated with the corresponding primers/adhesives (non-irradiated) and covered with a 100 μm-thick RLA layer (SC+A group). Three specimen series were additionally prepared (n = 3 × 5/material): A self-cured without the primers/adhesives (SC group), a dual-cured (20 s irradiation) with the corresponding primers/adhesives (DC+A group) and a dual-cured without primers/adhesives (DC group). All specimens were stored for 15 min (37 °C/dark/60 %RH). After demolding the degree of C = C conversion (DC%, top RLA surfaces) was measured by ATR-FTIR spectroscopy. The primer/adhesive liquids were further analyzed by ICP-MS and the microbrush tips of ADC by SEM-EDS.

Results: The touch-cure activators increased the DC% in all self-cured RLAs but failed to reach the values of the corresponding dual-cured RLAs. The effect of the activators in dual-cured specimens was negligible. The ICP-MS analysis showed the presence of V (AEP, TP5, ADC) and Cu (SUP) transitional metals in the activators, with V been located at the free ends of ADC tip bristles. The V activators demonstrated the highest DC% improvement in self-cured specimens.

Conclusion: The new touch-cure activators significantly increased the conversion of the self-cured RLAs. Therefore, this step should be considered as universally applicable and not selective, as currently proposed for the self-adhesive luting agents by the manufacturers.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jdent.2024.105147DOI Listing

Publication Analysis

Top Keywords

touch-cure activators
16
luting agents
12
degree conversion
8
conversion dual-cured
8
composite luting
8
prepared 5/material
8
corresponding primers/adhesives
8
primers/adhesives group
8
group dual-cured
8
activators increased
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!