Zr-based metalloporphyrin MOF probe for electrochemical detection of parathion-methyl.

Biosens Bioelectron

Technical University of Munich (TUM), School of Natural Sciences and Catalysis Research Center, Department of Chemistry, Chair of Inorganic and Metal-Organic Chemistry, Lichtenbergstraße 4, 85748, Garching, Germany. Electronic address:

Published: October 2024

An electrochemical (EC) sensor based on metalloporphyrin metal-organic framework (MOF) for the detection of parathion-methyl (PM) has been developed. The prepared MOF-525(Fe) exhibits great signal enhancement toward the electrochemical detection of PM owing to its unique structural properties and electrochemical activities. Under optimal experimental conditions, the as-prepared MOF-525(Fe) based EC sensor exhibited excellent PM sensing performance with a wide linear detection range (0.1 μM-100 μM) and low limit of detection (LOD, 1.4 nM). Compared to its corresponding Fe metalloporphyrin (linker), MOF-525(Fe) exhibited a superior sensitivity (28.31 μA cm·μM), which is 3.7 times higher than the sensitivity of FeTCPP linker (7.56 μA cm·μM) towards PM. The improved performance is associated with the high specific surface area and the large pore channels of MOF-525(Fe) facilitating a better interaction between PM and the Fe metalloporphyrin active sites, especially in the lower concentration range. Moreover, a possible affinity of the PM molecules toward Zr clusters may also contribute to the selective enrichment of PM on MOF-525(Fe). This EC sensor further demonstrated high selectivity in the presence of interfering molecules. The recovery results further confirm accurate PM sensing in actual samples, which suggests promising applications for the rapid detection of environmental organophosphates by metalloporphyrin MOFs.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.bios.2024.116515DOI Listing

Publication Analysis

Top Keywords

electrochemical detection
8
detection parathion-methyl
8
detection
6
mof-525fe
5
zr-based metalloporphyrin
4
metalloporphyrin mof
4
mof probe
4
electrochemical
4
probe electrochemical
4
parathion-methyl electrochemical
4

Similar Publications

This study aims to demonstrate that redox couples, regardless of their electrical charges, are unnecessary for detecting and quantifying electroactive proteins using an electrochemical sensor functionalized with a molecularly imprinted polymer. Our approach involved designing a polydopamine imprinted biosensor for detecting bovine serum albumin as the model protein. Electrochemical measurements were conducted in a phosphate-buffered solution (PBS) and solutions containing the negatively charged hexacyanoferrate, the neutral ferrocene, or the positively charged hexaammineruthenium (III) probes.

View Article and Find Full Text PDF

Biomimetic gastric microtissue electrochemical biosensors for ovalbumin detection.

Biosens Bioelectron

December 2024

College of Food Science and Engineering, Collaborative Innovation Center for Modern Grain Circulation and Safety, Key Laboratory of Grains and Oils Quality Control and Processing, Nanjing University of Finance and Economics, Nanjing, Jiangsu, 210023, PR China. Electronic address:

An innovative integrated three-dimensional (3D) bioprinted gastric microtissue electrochemical biosensor was developed in this study for the detection of allergen ovalbumin (OVA). In this system, OVA triggers the release of histamine from gastric microtissue, which then undergoes a redox reaction on the electrode surface, leading to an increase in the peak current. Gelatin methacrylate hydrogel serves as a scaffold for the 3D culture of RBL-2H3 and PC-12 cells for partially restoring allergic reactions in the human body in vitro.

View Article and Find Full Text PDF

A label-free electrochemical biosensor for sensitive analysis of the PARP-1 activity.

Bioelectrochemistry

December 2024

School of Chemistry and Chemical Engineering, Southeast University, Nanjing 211189, China. Electronic address:

Early diagnosis of tumors is becoming increasingly important in modern healthcare. As studies have demonstrated, Poly(ADP)ribose polymerase-1 (PARP-1) is overexpressed in more aggressive tumors. Consequently, sensitive detection of PARP-1 activity holds significant practical importance in clinical diagnostics and biomedical research.

View Article and Find Full Text PDF

Electrochemiluminescence (ECL) is nowadays a powerful technique widely used in biosensing and imaging, offering high sensitivity and specificity for detecting and mapping biomolecules. Screen-printed electrodes (SPEs) offer a versatile and cost-effective platform for ECL applications due to their ease of fabrication, disposability, and suitability for large-scale production. This research introduces a novel method for improving the ECL characteristics of screen-printed carbon electrodes (SPCEs) through the application of CO laser treatment following fabrication.

View Article and Find Full Text PDF

Low background catalytic redox recycling coupled with hybridization chain reaction amplification for highly sensitive electrochemical aptamer luteinizing hormone assay.

Bioelectrochemistry

December 2024

Key Laboratory of Luminescence Analysis and Molecular Sensing, Ministry of Education, School of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, PR China.

The concentration variation of luteinizing hormone (LH) regulates the cell cycle of oocyte meiosis and significantly affect the whole reproductive cycle. Sensitively quantifying the LH biomarker therefore plays an important role for reproductive disease diagnosis. By coupling a new low background catalytic redox recycling strategy with hybridization chain reaction (HCR), we propose a highly sensitive bio-electrochemical aptamer LH sensing method.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!