Carbapenem-resistant significant members of Acinetobacter calcoaceticus-Acinetobacter baumannii (CR-SM-ACB) complex have emerged as an important cause of sepsis, especially in ICUs. This study demonstrates the application of loop-mediated-isothermal-amplification (LAMP) assay for detection of CR-SM-ACB-complex from patients with sepsis. Whole-blood and culture-broths(CB) collected from patients with culture-positive sepsis were subjected to LAMP and compared with PCR, and RealAmp. Vitek-2 system and conventional PCR results were used as confirmatory references. The sensitivity and specificity of LAMP(97 % & 100 %) and RealAmp(100 % & 100 %) for detection of CR-SM-ACB-complex from CB were better than PCR(87 % & 100 %). Diagnostic accuracy of LAMP, RealAmp, and PCR for detection of SM-ACB-complex from CB was 98.5 %, 100 %, and 88.5 % respectively. Turnaround time of Culture, LAMP, PCR, and RealAmp was 28-53, 6-20, 9-23, and 6-20hours, respectively. LAMP is a simple, inexpensive tool that can be applied directly to positive CB and may be customized to detect emerging pathogens and locally-prevalent resistance genes and to optimize antimicrobial use.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.diagmicrobio.2024.116398 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!