Miniscrews are temporary skeletal anchorage devices that are widely used in orthodontic treatment, and their success depends on the placement area, angle, technique, and screw dimensions. This study aimed to investigate the effects of miniscrew lengths, insertion angles, and force directions on a mandible model consisting of teeth, cortical and cancellous bones. One Dental Volumetric Tomography (DVT) scan from a patient who had miniscrews were used for mandibular bone modeling to perform finite element analysis. The model variables included miniscrew lengths (6, 8, and 10 mm), insertion angles (-15°, 45°, 60°, and 90°), and force directions (30°, 45°, and 60°). The minimum and maximum stresses were calculated as 18.61 and 37.11 MPa at 6 mm and 10 mm, respectively. According to the insertion angles, the lowest stress was observed at 60°, while the highest stress was found at 15° in the ventral direction. At force directions, the lowest stress was at 60°, and the highest stress was at 45°. However, there were no significant differences in insertion angles and force directions. A statistically significant difference was determined in miniscrew length. As a result, the best result was calculated to be 6 mm inserted at a 60° angle, which could induce the lowest stress. Increasing the miniscrew length will increase the stress on the mandible. In addition, because of the higher force direction, stress decreases with shorter power arms.

Download full-text PDF

Source
http://dx.doi.org/10.1080/10255842.2024.2365909DOI Listing

Publication Analysis

Top Keywords

insertion angles
16
force directions
16
lowest stress
12
finite element
8
element analysis
8
miniscrew lengths
8
angles force
8
10 mm insertion
8
45° 60°
8
60° highest
8

Similar Publications

Neuraxial Anesthesia and Risk of Root Damage: A 3D Ex Vivo Study.

NeuroSci

December 2024

Laboratory of Surgical Neuroanatomy (LSNA), Human Anatomy and Embryology Unit, Faculty of Medicine and Health Sciences, Universitat de Barcelona, 08036 Barcelona, Spain.

Cauda equina nerve roots may become damaged during neuraxial anesthesia, and post-puncture headache may appear in the case of cerebrospinal fluid leakage if needle tips are deformed due to bone contact when several attempts are needed. Our aim was to verify the correlation between skin-transverse process distance (st) and skin-dural sac distance (d) for calculation of optimal angles in a free visual guide and as a reference for the maximal depth to be traversed by the needle. Randomly selected ex vivo samples ( = 10) were flexed to reproduce the position of the lumbosacral spine during spinal anesthesia.

View Article and Find Full Text PDF

Background: Low-frequency acupuncture is used to maintain skeletal muscle flexibility and improve joint range of motion; however, its definite effects are unclear. This study aimed to determine the effects of low-frequency acupuncture on muscle and fascial stiffness and ankle dorsiflexion range of motion.

Methods: The participants included 12 randomly selected healthy adults.

View Article and Find Full Text PDF

Background: Lumbar degenerative diseases are an important factor in disability worldwide, and they are also common among the elderly population. Stand-Alone Oblique Lumbar Interbody Fusion (Stand-Alone OLIF) is a novel surgical approach for treating lumbar degenerative diseases. However, long-term follow-up after surgery has revealed the risk of endplate collapse associated with Stand-Alone OLIF procedures.

View Article and Find Full Text PDF

Robotic Versus Manual Electrode Insertion in Cochlear Implant Surgery: An Experimental Study.

Clin Exp Otorhinolaryngol

December 2024

King Abdullah Ear Specialist Center (KAESC), King Saud Medical City, King Saud University, Riyadh 11411, Saudi Arabia.

Objectives: This experimental study compares the precision and surgical outcomes of manual versus robotic electrode insertions in cochlear implantation.

Methods: Conducted on formalin-fixed cadaveric heads, the study involved nine senior neurotologists performing both manual and robotic insertions.

Results: The results showed no statistically significant difference between the two methods in insertion angle, cochlear coverage, or electrode coverage.

View Article and Find Full Text PDF

Background: Postoperative osteolysis may be observed around poly-l-lactic acid (PLLA) pins in osteochondral fragments fixation for an osteochondral lesion of the talus (OLT). Hydroxyapatite (HA) improves biocompatibility, osteoconductivity, and mechanical strength when added to PLLA. This study aimed to compare the characteristics of osteolysis and clinical outcomes of fixation for OLT with PLLA pins vs PLLA/HA pins.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!