Low-cost markerless motion capture systems offer the potential for 3D measurement of joint angles during human movement. This study aimed to validate a smartphone-based markerless motion capture system's (OpenCap) derived lower extremity kinematics during common return-to-sport tasks, comparing it to an established optoelectronic motion capture system. Athletes with prior anterior cruciate ligament reconstruction (12-18 months post-surgery) performed three movements: a jump-landing-rebound, single-leg hop, and lateral-vertical hop. Kinematics were recorded concurrently with two smartphones running OpenCap's software and with a 10-camera, marker-based motion capture system. Validity of lower extremity joint kinematics was assessed across 437 recorded trials using measures of agreement (coefficient of multiple correlation: CMC) and error (mean absolute error: MAE, root mean squared error: RMSE) across the time series of movement. Agreement was best in the sagittal plane for the knee and hip in all movements (CMC > 0.94), followed by the ankle (CMC = 0.84-0.93). Lower agreement was observed for frontal (CMC = 0.47-0.78) and transverse (CMC = 0.51-0.6) plane motion. OpenCap presented a grand mean error of 3.85° (MAE) and 4.34° (RMSE) across all joint angles and movements. These results were comparable to other available markerless systems. Most notably, OpenCap's user-friendly interface, free software, and small physical footprint have the potential to extend motion analysis applications beyond conventional biomechanics labs, thus enhancing the accessibility for a diverse range of users.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jbiomech.2024.112200DOI Listing

Publication Analysis

Top Keywords

motion capture
20
markerless motion
12
capture system
12
low-cost markerless
8
return-to-sport tasks
8
joint angles
8
lower extremity
8
motion
7
capture
5
validation opencap
4

Similar Publications

Background: Gait analysis is traditionally conducted using marker-based methods yet markerless motion capture is emerging as an alternative. Initial studies have begun to evaluate the reliability of markerless motion capture yet the evaluation of different clothing conditions across sessions and complete evaluation of the lower limb and pelvis reliability have yet to be considered. The aim of this study was to evaluate the inter-trial, inter-session and inter-session-clothing variation and root mean square differences between tight- or loose-fitting clothing during walking.

View Article and Find Full Text PDF

Provider kinematic strategies during the delivery of spinal manipulation and mobilization: a scoping review of the literature.

Chiropr Man Therap

January 2025

Department of Chiropractic Medicine, Integrative Spinal Research Group, Balgrist University Hospital, University of Zurich, Zurich, Switzerland.

Background: Spinal manipulation (MAN) and mobilization (MOB) are biomechanically different yet both elicit pain reduction and increased range of motion. Previous investigations have focused on quantifying kinetics (e.g.

View Article and Find Full Text PDF

Fatigue is prevalent in immune-mediated inflammatory and neurodegenerative diseases, yet its assessment relies largely on patient-reported outcomes, which capture perception but not fluctuations over time. Wearable sensors, like inertial measurement units (IMUs), offer a way to monitor daily activities and evaluate functional capacity. This study investigates the relationship between sit-to-stand and stand-to-sit transitions and self-reported physical and mental fatigue in participants with Parkinson's, Huntington's, rheumatoid arthritis, systemic lupus erythematosus, primary Sjögren's syndrome and inflammatory bowel disease.

View Article and Find Full Text PDF

Sternum drop as a kinematic measure of trip recovery performance.

J Biomech

January 2025

Grado Department of Industrial and Systems Engineering, Virginia Tech, 250 Durham Hall (0118), 1145 Perry Street, Blacksburg, VA 24061, USA. Electronic address:

Deficient trip recovery kinematics have been implicated in many trip-induced falls. Three key requisites for successful trip recovery include limiting trunk flexion, maintaining adequate hip height to enable repeated stepping, and completing recovery steps to extend the base of support. The purpose of this study was to evaluate sternum drop as a new measure of trip recovery performance.

View Article and Find Full Text PDF

Purpose: This biomechanical study aimed to investigate the effectiveness of a hinged elbow orthosis in reducing passive valgus forces following medial ulnar collateral ligament (UCL) injuries of the elbow joint. The hypothesis tested was that a hinged elbow orthosis reduces these passive valgus forces.

Methods: Eight fresh frozen cadaveric elbow specimens were prepared and tested under three scenarios: intact ligaments, simulated UCL rupture and application of a hinged elbow brace after simulated UCL rupture.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!