A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Repositioning of the Insertable Cardiac Monitor Through the Same Incision to Avoid T-wave Oversensing. | LitMetric

Insertable cardiac monitor (ICM), used for long-term heart rhythm monitoring, often experiences diagnostic challenges such as T-wave oversensing, leading to false positives. This case report presents a novel approach to rectifying T-wave oversensing in ICM implantations. In this case, we are sharing a 38-year-old female with recurrent syncopal episodes who underwent ICM implantation (LUX-Dx™, ICM-Boston Scientific, Marlborough, United States). Post-implantation, T-wave oversensing was detected. Instead of the usual readjustment or reinsertion, we employed a non-invasive method of repositioning the ICM at a 45-degree angle toward the right side of the heart through the existing incision. This effectively resolved the oversensing issue without complications or the need for a new incision. ICMs are vital in linking symptoms to arrhythmias, especially in cases where standard diagnostic tools fall short. Despite their utility, ICMs are susceptible to T-wave oversensing due to subcutaneous placement. Our case demonstrates a successful alternative approach to address this, enhancing ICM's diagnostic accuracy without invasive procedures. This case highlights the potential of repositioning ICMs as a simple, non-invasive solution to overcome T-wave oversensing issues. It calls for further research and discussion within the medical community to explore its wider applicability, thereby improving ICM efficacy in clinical practice. The patient experienced no complications following the procedure during the three-month visit with appropriate sensing, validating this approach as a feasible option in similar cases.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11187785PMC
http://dx.doi.org/10.7759/cureus.60741DOI Listing

Publication Analysis

Top Keywords

t-wave oversensing
24
insertable cardiac
8
cardiac monitor
8
oversensing
7
t-wave
6
icm
5
repositioning insertable
4
monitor incision
4
incision avoid
4
avoid t-wave
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!