Background: Healthcare providers have faced challenges for patients with moderate and severe chronic obstructive pulmonary disease (COPD) in conducting their pulmonary rehabilitation due to dyspnea and exercise intolerance. Neuromuscular electrical stimulation (NMES) has been used to improve the muscle group's power and endurance without adding pulmonary workload, which might be used as a potential adjuvant rehabilitation method and thus to improve patients' pulmonary functions.

Methods: This was a systematic review and meta-analysis of randomized controlled trials. Data were retrieved from PubMed, CINAHL, Academic Search Complete, Cochrane Library, and Airiti Library databases from the inception of the database to December 2022. The Cochrane Collaboration tool was used to assess the risk of bias. Two reviewers independently assessed, extracted, and appraised the included studies. Then, the grading of recommendations, assessment, development, and evaluation (GRADE) methodology was used for assessing the certainty of evidence. The pooled estimates were calculated using a random-effects model.

Results: In total, 19 studies involving 589 moderate to severe COPD patients were analyzed. Compared with controls, adding NMES to pulmonary rehabilitation could significantly increase exercise capacity, physical activity function, and health-related quality of life (HRQoL) (all p < 0.05). The GRADE results showed low to very low certainty of evidence levels.

Conclusion: NMES could improve exercise capacity and reduce the perceived sensation of dyspnea during exercise and is recommended as an effective adjuvant training modality in the rehabilitation for moderate to severe COPD patients.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ctcp.2024.101867DOI Listing

Publication Analysis

Top Keywords

moderate severe
12
neuromuscular electrical
8
electrical stimulation
8
patients moderate
8
severe chronic
8
chronic obstructive
8
obstructive pulmonary
8
pulmonary disease
8
systematic review
8
review meta-analysis
8

Similar Publications

Background: Insomnia is a prevalent sleep disorder affecting millions worldwide, with significant impacts on daily functioning and quality of life. While traditionally assessed through subjective measures such as the Insomnia Severity Index (ISI), the advent of wearable technology has enabled continuous, objective sleep monitoring in natural environments. However, the relationship between subjective insomnia severity and objective sleep parameters remains unclear.

View Article and Find Full Text PDF

Background: An effective primary treatment for obsessive-compulsive disorder (OCD) in children and adolescents as well as adults is exposure and response prevention (ERP), a form of intervention in the context of cognitive-behavioral therapy. Despite strong evidence supporting the efficacy and effectiveness of ERP from studies in research and real-world settings, its clinical use remains limited. This underuse is often attributed to access barriers such as the scarcity of properly trained therapists, geographical constraints, and costs.

View Article and Find Full Text PDF

The purpose of this study was to evaluate the radiographic outcomes of distal chevron metatarsal osteotomy associated with lateral joint capsule split as only lateral soft tissue release in patients with symptomatic moderate and severe hallux valgus (HV) deformity. Ninety patients (103 feet) at our institution between January 2014 and December 2019 were included in the present retrospective study. Each patient was evaluated preoperatively and at final follow-up by means of weight bearing radiographs lateral and dorsoplantar views.

View Article and Find Full Text PDF

This case report highlights a potential vaccine safety concern associated with the Pseudorabies virus (PRV) live vaccine, which warrants further investigation for comprehensive understanding. Vaccine-induced immune thrombotic thrombocytopenia (VITT), a novel syndrome of adverse events following adenovirus vector COVID-19 vaccines, was observed after vaccination with Zoetis PR-VAC PLUS. This led to a 100% morbidity and high mortality among PRV-free Danish purebred pigs from Danish Genetics Co.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!