A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Effect of Digital Early Warning Scores on Hospital Vital Sign Observation Protocol Adherence: Stepped-Wedge Evaluation. | LitMetric

AI Article Synopsis

  • Early warning scores (EWS) are used in hospitals to assess patients' risk of becoming worse, but their effectiveness and impact on patient management have been unclear.
  • This study compared paper observation charts with a digital EWS system across four hospitals to see if the digital version led to more frequent observations of patients with alarming vital signs.
  • Results showed no significant difference in the time to observe patients or other key outcomes, indicating that while the digital system was well-received, it did not improve the management of deteriorating patients.

Article Abstract

Background: Early warning scores (EWS) are routinely used in hospitals to assess a patient's risk of deterioration. EWS are traditionally recorded on paper observation charts but are increasingly recorded digitally. In either case, evidence for the clinical effectiveness of such scores is mixed, and previous studies have not considered whether EWS leads to changes in how deteriorating patients are managed.

Objective: This study aims to examine whether the introduction of a digital EWS system was associated with more frequent observation of patients with abnormal vital signs, a precursor to earlier clinical intervention.

Methods: We conducted a 2-armed stepped-wedge study from February 2015 to December 2016, over 4 hospitals in 1 UK hospital trust. In the control arm, vital signs were recorded using paper observation charts. In the intervention arm, a digital EWS system was used. The primary outcome measure was time to next observation (TTNO), defined as the time between a patient's first elevated EWS (EWS ≥3) and subsequent observations set. Secondary outcomes were time to death in the hospital, length of stay, and time to unplanned intensive care unit admission. Differences between the 2 arms were analyzed using a mixed-effects Cox model. The usability of the system was assessed using the system usability score survey.

Results: We included 12,802 admissions, 1084 in the paper (control) arm and 11,718 in the digital EWS (intervention) arm. The system usability score was 77.6, indicating good usability. The median TTNO in the control and intervention arms were 128 (IQR 73-218) minutes and 131 (IQR 73-223) minutes, respectively. The corresponding hazard ratio for TTNO was 0.99 (95% CI 0.91-1.07; P=.73).

Conclusions: We demonstrated strong clinical engagement with the system. We found no difference in any of the predefined patient outcomes, suggesting that the introduction of a highly usable electronic system can be achieved without impacting clinical care. Our findings contrast with previous claims that digital EWS systems are associated with improvement in clinical outcomes. Future research should investigate how digital EWS systems can be integrated with new clinical pathways adjusting staff behaviors to improve patient outcomes.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11224703PMC
http://dx.doi.org/10.2196/46691DOI Listing

Publication Analysis

Top Keywords

digital ews
20
ews
10
early warning
8
warning scores
8
recorded paper
8
paper observation
8
observation charts
8
ews system
8
vital signs
8
control arm
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!