Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 143
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 143
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 209
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 994
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3134
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
The analysis of traces of injuries can be difficult in cases of charred human remains since the alteration and fragmentation are high. The aim of this study is to explore the use of X-Ray Fluorescence (XRF) technique as a screening tool for detecting and analyzing gunshot residues (GSR) on cremated and highly fragmented materials, as it is a technique that allows for fast qualitative investigations without altering the sample or requiring sample preparation. The study was carried out on two steps: firstly, on completed skeletonized bones to verify if GSR survive to burning; secondly, we considered a more realistic situation, in which soft tissues were present before the shooting. To this aim, nine adult bovine ribs, four retaining soft tissue, five completely skeletonized, were subjected to a shooting test using two types of 9 mm projectiles (jacketed and unjacketed bullets). The ribs were then burnt until complete calcination in an electric furnace. The entry wound of each rib was analyzed using XRF, revealing traces of GSR. The XRF analysis showed that all samples, except for one, contain Pb and/or Sb near the lesion. Furthermore, the samples hit by unjacketed bullets had a more significant presence of Pb in macroscopic yellow areas, which persisted when moving away from the gunshot. These findings could pave the way for the use of XRF technology, mostly when a fast and immediate scan must be done on osteologic materials by a conservative method.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11490517 | PMC |
http://dx.doi.org/10.1007/s00414-024-03274-4 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!