Significant progress has been made in recent years in the development of techniques for Next Generation Sequencing (NGS), or Massively Parallel Sequencing (MPS), of forensically relevant short tandem repeat (STR) loci. However, as these technologies are investigated and adopted by forensic laboratories, new challenges unfold that require further scrutiny. In the analysis of DNA profiles generated using the MiSeq FGx sequencing system, we have observed noise sequences with relatively high readcounts that are challenging to distinguish from genuine alleles. These high read count noise sequences appear as allele sequences with one or a few substituted bases compared to a known allele sequence within the profile. An examination of ForenSeq DNA Signature Prep Kit STR noise sequences revealed that the substituted base of a parent allele can align to the same position on the sequence across noise sequences. This suggests that these substitution events occur at specific positions within the amplicon, resulting in multiple noise reads with substitutions at the same position. Mapping of the noise events onto the original raw read positions revealed a high number of events, or "noise spikes", occurring at specific positions within a given sequencing run. These noise spikes affected reads across the entire run, agnostic of locus or sample, while the position, occurrence, and amplitude of the spikes differed across runs. The majority of noise sequences with high read counts in a DNA profile were generated from base changes at these spike positions, and could be classified as "noise spike artefacts". In this paper we present evidence of the noise spike artefacts and their genesis during the sequencing process in the sequencing-by-synthesis (SBS) cycles, as well as the methods developed to detect them. The information and methods will assist laboratories with detecting noise spikes in MiSeq FGx sequencing runs, differentiating authentic allele sequences from noise spike artefacts, and developing protocols for analyst review and handling of MiSeq FGx data.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.fsigen.2024.103086 | DOI Listing |
Acad Radiol
January 2025
Department of Radiology, Kantonsspital Baden, affiliated Hospital for Research and Teaching of the Faculty of Medicine of the University of Zurich, Im Ergel 1, 5404 Baden, Switzerland (D.H., A.M., R.R., J.H., R.A.K.-H.).
Rationale And Objectives: The aim of this study was to compare the image quality of a deep learning (DL)-accelerated volumetric interpolated breath-hold examination (VIBE) sequence with a standard (ST) VIBE sequence in assessing the uterus.
Materials And Methods: Between April and December 2023, a total of 61 female patients (aged 41 ± 14 years) who were referred for an magnetic resonance imaging (MRI) of the pelvis were included in this prospective study, after providing informed consent. All examinations were performed with a 1.
Hemasphere
January 2025
Department of Internal Medicine, Hematology and Oncology, and Institute of Medical Genetics and Genomics, University Hospital Brno and Medical Faculty Masaryk University Brno Czech Republic.
In chronic lymphocytic leukemia, the reliability of next-generation sequencing (NGS) to detect variants ≤10% allelic frequency (low-VAF) is debated. We tested the ability to detect 23 such variants in 41 different laboratories using their NGS method of choice. The sensitivity was 85.
View Article and Find Full Text PDFFront Neurosci
January 2025
School of Electronic Information and Communications, Huazhong University of Science and Technology, Wuhan City, China.
Introduction: Transcranial magnetic stimulation (TMS) is widely used for the noninvasive activation of neurons in the human brain. It utilizes a pulsed magnetic field to induce electric pulses that act on the central nervous system, altering the membrane potential of nerve cells in the cerebral cortex to treat certain mental diseases. However, the effectiveness of TMS can be compromised by significant heat generation and the clicking noise produced by the pulse in the TMS coil.
View Article and Find Full Text PDFJ Perinat Neonatal Nurs
January 2025
Author Affiliations: Department of Pediatric and Neonatal Nursing, School of Nursing and Midwifery, Mashhad University of Medical Sciences, Mashhad, Iran (Mrs Mohseni and Dr Ramezani); Nursing and Midwifery Care Research Center, Mashhad University of Medical Sciences, Mashhad, Iran Mrs (Dr Ramezani); Department of Epidemiology and Biostatistics, School of Health, Mashhad University of Medical Sciences, Mashhad, Iran (Dr Saki); and Neonatologist, NICU Department, Hakim Hospital, Neyshabur University of Medical Sciences, Neyshabur, Iran (Dr Poor-Alizadeh).
With the increasing survival rates of premature infants and their associated respiratory problems, noninvasive ventilation has gained popularity in neonatal intensive care units. On the other hand, this equipment can be stressful for infants. Objective: This study aimed to compare the effects of white noise and sound reduction on the behavioral responses of premature infants under noninvasive ventilation.
View Article and Find Full Text PDFJ Magn Reson Imaging
January 2025
Department of Radiology, Nanjing Drum Tower Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing, Jiangsu, China.
Background: At high magnetic fields, degraded image quality due to dielectric artifacts and elevated specific absorption rate (SAR) are two technical challenges in fetal MRI.
Purpose: To assess the potential of high dielectric constant (HDC) pad in increasing image quality and decreasing SAR for 3 T fetal MRI.
Study Type: Prospective.