As an important part of the membrane field, hollow fiber membranes (HFM) have been widely concerned by scholars. HFM fouling in the industrial application results in a reduction in its lifespan and an increase in cost. In recent years, various explorations on the HFM fouling control strategies have been carried out. In the current work, we critically review the influence of flow field characteristics in HFM-based bioreactor on membrane fouling control. The flow field characteristics mainly refer to the spatial and temporal variation of the related physical parameters. In the HFM field, the physical parameter mainly refers to the variation characteristics of the shear force, flow velocity and turbulence caused by hydraulics. The factors affecting the flow field characteristics will be discussed from three levels: the micro-flow field near the interface of membrane (micro-interface), the flow field around the membrane module and the reactor design related to flow field, which involves surface morphology, crossflow, aeration, fiber packing density, membrane vibration, structural design and other related parameters. The study of flow field characteristics and influencing factors in the HFM separation process will help to improve the performance of HFM in full-scale water treatment plants.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jenvman.2024.121525 | DOI Listing |
Am J Ophthalmol Case Rep
March 2025
Department of Ophthalmology, Shinshu University School of Medicine, Japan.
Purpose: To report a case of a diabetic patient undergoing rapid glycemic improvement characterized by the development and resolution of cotton wool spot (CWS), with detailed structural and vascular assessment using wide-field multimodal imaging, including wide-field color fundus photography and wide-field optical coherence tomography angiography (OCTA).
Observations: A 47-year-old man with poorly controlled Type 2 diabetes mellitus developed CWS in his right eye 3 months after initiating insulin therapy, which coincided with a significant reduction in HbA1c levels. Wide-field color fundus photography and wide-field OCTA were performed before, during, and after CWS appeared.
Stroke Vasc Neurol
January 2025
Department of Neurology, Beijing Tiantan Hospital, Beijing, China
Background: Stroke remains a major global health challenge, with China experiencing a significant burden due to its high incidence and severe outcomes. Reperfusion therapies, such as intravenous thrombolysis and endovascular thrombectomy, have shown substantial benefits in improving early outcomes for ischaemic stroke. Recent clinical trials have validated the safety and efficacy of a broader range of thrombolytic agents and expanded the eligible patient populations for both intravenous thrombolysis and mechanical thrombectomy.
View Article and Find Full Text PDFAnal Chim Acta
February 2025
Ministry of Education Key Laboratory for the Synthesis and Application of Organic Functional Molecules, Hubei Key Laboratory for Precision Synthesis of Small Molecule Pharmaceuticals, College of Chemistry and Chemical Engineering, Hubei University, Wuhan, 430062, PR China; Key Laboratory of Advanced Energy Materials Chemistry (Ministry of Education), Nankai University, Tianjin, 300071, PR China. Electronic address:
Background: Traditional lateral flow biosensors (LFBs), which utilize colorimetric signals as output, possess the virtues of simplicity and rapidity. However, it also suffers from insufficient sensitivity and limited reliability. It is well known that the results of LFBs can be false positive, and it is difficult to perform accurate quantification under low-abundance targets.
View Article and Find Full Text PDFLuminescence
January 2025
Department of Mathematical and Natural Sciences, Özyeğin University, Istanbul, Türkiye.
The present study introduces the idea of a novel fluorescence-based imaging technique combined with a microfluidic platform that enables a precise control of dark transient state populations of fluorescent probes flowing over a uniform, top flat supergaussian excitation field with a constant flow rate. To demonstrate the imaging capability of the proposed detection method, numerical simulations have been performed by considering laser, microscope and flow parameters of experimental setup together with photophysical model and electronic transition rates of fluorescent dyes. As an output data to be assessed, fluorescence image data is simulated numerically for bromine-free carboxyfluorescein and its brominated derivatives having different numbers of bromine atoms.
View Article and Find Full Text PDFNeuroradiology
January 2025
Department of Molecular Imaging and Diagnosis, Graduate School of Medical Sciences, Kyushu University, 3-1-1, Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan.
Background And Purpose: The cortical high-flow sign has been more commonly reported in oligodendroglioma, IDH-mutant and 1p/19q-codeleted (ODG IDHm-codel) compared to diffuse glioma with IDH-wildtype or astrocytoma, IDH-mutant. Besides tumor types, higher grades of glioma might also contribute to the cortical high flow. Therefore, we investigated whether the histological cortical vascular density or CNS WHO grade was associated with the cortical high-flow sign in patients with ODG IDHm-codel.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!