Purpose: To investigate the factors associated with and impact on the femtosecond-assisted (FS-assisted) limbal relaxing incision (LRI) combined with the steep-meridian tri-planar clear corneal incision (TCCI) to reduce astigmatism in patients undergoing Implantable Collamer Lens (ICL) surgery.
Methods: Retrospective case series. The study reviewed patients with ICL surgery combined with FS-assisted LRIs paired with steep-meridian TCCIs. Correlation analysis examined the relationship between independent variables, including preoperative characteristics (intraocular pressure, corneal thickness, axial length, et al.), TCCI, and LRI surgical parameters. The predictors of surgically induced astigmatism (SIA) were determined using individual-level analysis and accounting for inter-eye correlation with the generalized estimating equation (GEE).
Results: The study enrolled 69 patients, with 114 eyes (55 right and 59 left). The mean spherical equivalent (SEQ) was - 10.29 ± 2.99D and - 9.99 ± 2.72D for the right and left eye, respectively, while the mean preoperative corneal astigmatism was - 1.54 ± 0.47D and - 1.54 ± 0.46D for the right and left eyes, respectively. After 12 months of follow-up, univariate analysis revealed significant correlations between SIA and intraocular pressure (IOP), astigmatism type, TCCI position (degree), peripheral corneal thickness (PCT), LRI arc incision diameter, post depth (%), and angle, respectively (P = 0.046, 0.016, 0.039, 0.040, 0.009, 0.000, 0.000). Multivariate analysis using GEE demonstrated that axial length (AL), astigmatism type, LRI arc diameter, and angle were independent predictors of SIA (P = 0.000, 0.005, 0.029, 0.000).
Conclusions: The type of astigmatism and axial length were independent factors that affected SIA when modifying the LRI arc diameter and angle through FS-assisted steep-meridian TCCI paired with LRI in ICL surgery.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00417-024-06547-1 | DOI Listing |
J Mol Model
January 2025
School of Mechanics and Safety Engineering, Zhengzhou University, Zhengzhou, 450001, People's Republic of China.
Context: SiGe nanotubes (SiGeNTs) hold significant promise for applications in nanosolar cells, optoelectronic systems, and interconnects, where thermal conductivity is critical to performance. This study investigates the effects of length, diameter, temperature, and axial strain on the thermal conductivity of armchair and zigzag SiGeNTs through molecular dynamics simulations. Results indicate that thermal conductivity increases with sample length due to ballistic heat transport and decreases with temperature as phonon scattering intensifies.
View Article and Find Full Text PDFInvest Ophthalmol Vis Sci
January 2025
Department of Ophthalmology, Saitama Medical University, Saitama, Japan.
Purpose: This study evaluates the effect of 6° horizontal gaze tolerance on visual field mean sensitivity (MS) in patients with glaucoma using a binocular head-mounted automated perimeter, following findings of structural changes in the posterior globe from magnetic resonance imaging and optical coherence tomography.
Methods: In this cross-sectional study, a total of 161 eyes (85 primary open-angle glaucoma [POAG] and 76 healthy) from 117 participants were included. Logistic regression and 1:1 matched analysis assessed the propensity score for glaucoma and healthy eyes, considering age, sex, and axial length as confounders.
Pak J Med Sci
January 2025
Sasankoti Mohan Ravi Prakash, DMD, MDS, BDS Dentist and Independent Researcher, Hope Health Inc, 360 N Irby St. Florence, South Carolina, USA 29501.
Background & Objective: Currently, there are many implants in clinical use, making it hard to choose the right one for the patient. The success rate of an implant depends on its diameter, length, and direction of insertion in bone. In implant dentistry, Finite Element Analysis (FEA) simulates intraoral conditions in vitro and analyzes the effects of implant material, diameter, size, and other components related to oral structure on the implant and peri-implant tissues.
View Article and Find Full Text PDFClin Ophthalmol
January 2025
Department of Ophthalmology, Saitama Medical Center, Saitama Medical University, Kawagoe-shi, Saitama, Japan.
Purpose: Among patients with angle-closure glaucoma, it is common to have a short-axial eye, which also makes it difficult to select an appropriate intraocular lens. Previous studies have focused on the ocular biometry of the long-axial eye, whereas only a few reports have focused on the short-axial eye. This study aimed to clarify the characteristics of the short-axial eye on ocular biometry among the elderly Japanese.
View Article and Find Full Text PDFJ Orthop Surg Res
January 2025
Department of Orthopedic Surgery, Affiliated Hospital of Xuzhou Medical University, 99 Huaihai Road, Xuzhou, Jiangsu, 221002, China.
Purpose: To compare the efficacy and safety of skip titanium plates combined with adjacent spinous process suture suspension versus continuous titanium plate fixation in cervical laminoplasty.
Methods: A retrospective analysis of 125 patients (62 men, 63 women, average age 60.9 ± 10.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!