Noise Reduction and Localization Accuracy in a Mobile Magnetoencephalography System.

Sensors (Basel)

Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham NG7 2RD, UK.

Published: May 2024

Magnetoencephalography (MEG) non-invasively provides important information about human brain electrophysiology. The growing use of optically pumped magnetometers (OPM) for MEG, as opposed to fixed arrays of cryogenic sensors, has opened the door for innovation in system design and use cases. For example, cryogenic MEG systems are housed in large, shielded rooms to provide sufficient space for the system dewar. Here, we investigate the performance of OPM recordings inside of a cylindrical shield with a 1 × 2 m footprint. The efficacy of shielding was measured in terms of field attenuation and isotropy, and the value of post hoc noise reduction algorithms was also investigated. Localization accuracy was quantified for 104 OPM sensors mounted on a fixed helmet array based on simulations and recordings from a bespoke current dipole phantom. Passive shielding attenuated the vector field magnitude to 50.0 nT at direct current (DC), to 16.7 pT/√Hz at power line, and to 71 fT/√Hz (median) in the 10-200 Hz range. Post hoc noise reduction provided an additional 5-15 dB attenuation. Substantial field isotropy remained in the volume encompassing the sensor array. The consistency of the isotropy over months suggests that a field nulling solution could be readily applied. A current dipole phantom generating source activity at an appropriate magnitude for the human brain generated field fluctuations on the order of 0.5-1 pT. Phantom signals were localized with 3 mm localization accuracy, and no significant bias in localization was observed, which is in line with performance for cryogenic and OPM MEG systems. This validation of the performance of a small footprint MEG system opens the door for lower-cost MEG installations in terms of raw materials and facility space, as well as mobile imaging systems (e.g., truck-based). Such implementations are relevant for global adoption of MEG outside of highly resourced research and clinical institutions.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11174973PMC
http://dx.doi.org/10.3390/s24113503DOI Listing

Publication Analysis

Top Keywords

noise reduction
12
localization accuracy
12
human brain
8
opm meg
8
meg systems
8
post hoc
8
hoc noise
8
current dipole
8
dipole phantom
8
meg
7

Similar Publications

The time-resolved detection of mid- to far-infrared electric fields absorbed and emitted by molecules is among the most sensitive spectroscopic approaches and has the potential to transform sensing in fields such as security screening, quality control, and medical diagnostics. However, the sensitivity of the standard detection approach, which relies on encoding the far-infrared electric field into amplitude modulation of a visible or near-infrared probe laser pulse, is limited by the shot noise of the latter. This constraint cannot be overcome without using a quantum resource.

View Article and Find Full Text PDF

Active headrest combined with a depth camera-based ear-positioning system.

J Acoust Soc Am

January 2025

Key Laboratory of Modern Acoustic, Nanjing University, Nanjing 210093, China.

Due to the limited size of the quiet zone created by active headrests (AHR) near the human ear, noise reduction (NR) at the human ear decreases dramatically when the head moves. Combined with a head tracking system can improve the NR performance when the head moves, but most such studies currently only consider head translation. To improve the robustness when the head translates or rotates, an ear-positioning (EP) system based on a depth camera and human pose estimation model is presented in this paper and integrated with AHR.

View Article and Find Full Text PDF

Rapid Acquisition of High-Pixel Fluorescence Lifetime Images of Living Cells via Image Reconstruction Based on Edge-Preserving Interpolation.

Biosensors (Basel)

January 2025

State Key Laboratory of Radio Frequency Heterogeneous Integration (Shenzhen University), Key Laboratory of Optoelectronic Devices and Systems of Ministry of Education and Guangdong Province, College of Physics and Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, China.

Fluorescence lifetime imaging (FLIM) has established itself as a pivotal tool for investigating biological processes within living cells. However, the extensive imaging duration necessary to accumulate sufficient photons for accurate fluorescence lifetime calculations poses a significant obstacle to achieving high-resolution monitoring of cellular dynamics. In this study, we introduce an image reconstruction method based on the edge-preserving interpolation method (EPIM), which transforms rapidly acquired low-resolution FLIM data into high-pixel images, thereby eliminating the need for extended acquisition times.

View Article and Find Full Text PDF

Numerous efforts have been invested in previous algorithms to expose and enhance blood vessel (BV) visibility derived from clinical coronary angiography (CAG) procedures, such as noise reduction, segmentation, and background subtraction. Yet, the visibility of the BVs and their luminal content, particularly the small ones, is still limited. We propose a novel visibility enhancement algorithm, whose main body is inspired by a line completion mechanism of the visual system, i.

View Article and Find Full Text PDF

Improved Entropy-Based Condition Monitoring for Pressure Pipeline Through Acoustic Denoising.

Entropy (Basel)

December 2024

Jiangsu Frontier Electric Technology Co., Ltd., Nanjing 211102, China.

During long-term operation in complex environments, the pressure pipeline systems are prone to damage and faults, and serious safety accidents may occur without real-time condition monitoring. Moreover, in traditional non-contact monitoring approaches, acoustic signals are widely employed for condition monitoring for pressure pipelines, which are easily contaminated by background noise and provide unsatisfactory accuracy. As a tool for quantifying uncertainty and complexity, signal entropy is applied to detect abnormal conditions.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!