A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Flow cytometric analysis of peripheral blood neutrophil myeloperoxidase expression in myelodysplastic neoplasms (MPO-MDS-Valid): protocol for a multicentre diagnostic accuracy study. | LitMetric

AI Article Synopsis

  • A study is investigating whether flow cytometric analysis of myeloperoxidase expression in peripheral blood can accurately rule out myelodysplastic neoplasm (MDS), potentially reducing unnecessary bone marrow aspirations for about 35% of patients.
  • The MPO-MDS-Valid project involves recruiting 400 patients from multiple hospitals in France to validate the testing method by comparing it to established diagnoses made by experienced hematopathologists.
  • The research has been ethically approved, and results will be shared through publication to inform medical practice and improve patient care.

Article Abstract

Introduction: Many patients referred for suspicion of myelodysplastic neoplasm (MDS) are subjected to unnecessary discomfort from bone marrow aspiration, due to the low disease prevalence in this population. Flow cytometric analysis of peripheral blood neutrophil myeloperoxidase expression could rule out MDS with sensitivity and negative predictive value estimates close to 100%, ultimately obviating the need for bone marrow aspiration in up to 35% of patients. However, the generalisability of these findings is uncertain due to the limited sample size, the enrolment of patients at a single study site, and the reliability issues associated with laboratory-developed tests and varying levels of operator experience. This study aims to validate the accuracy attributes of peripheral blood neutrophil myeloperoxidase expression quantified by flow cytometric analysis in an independent multicentre sample.

Methods And Analysis: The MPO-MDS-Valid project is a cross-sectional diagnostic accuracy study comparing an index test to a reference standard. Consecutive adult patients referred for suspicion of MDS are being recruited at seven university hospitals and one cancer centre in France. At each site, flow cytometric analysis of peripheral blood samples is performed by operators who are blinded to the reference diagnosis. A central adjudication committee whose members are unaware of the index test results will determine the reference diagnosis of MDS, based on cytomorphological evaluation of bone marrow performed in duplicate by experienced hematopathologists. The target sample size is 400 patients and the anticipated study recruitment completion date is 31 December 2025.

Ethics And Dissemination: An institutional review board (Comité de Protection des Personnes Nord-Ouest III, Caen, France) approved the protocol, prior to the start of the study. Participants are recruited using an opt-out approach. Efforts will be made to publish the primary results within 6 months after study completion.

Trial Registration Number: NCT05175469.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11191800PMC
http://dx.doi.org/10.1136/bmjopen-2023-081200DOI Listing

Publication Analysis

Top Keywords

flow cytometric
16
cytometric analysis
16
peripheral blood
16
analysis peripheral
12
blood neutrophil
12
neutrophil myeloperoxidase
12
myeloperoxidase expression
12
bone marrow
12
diagnostic accuracy
8
accuracy study
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!