NeutralNet: Development and testing of a machine learning solution for pulse shape discrimination.

Appl Radiat Isot

Department of Physics and Astronomy, McMaster University, Hamilton, ON, L8S 4K1, Canada. Electronic address:

Published: September 2024

AI Article Synopsis

Article Abstract

Accurate description of radiation fields containing neutrons continues to be a difficult task to complete. This difficulty arises because of the inherent sensitivity of neutron detectors to other types of radiation, and the ability of neutrons to generate secondary particles producing mixed field environments. This research looks at the development and performance of various machine learning architectures when applied to the task of pulse shape discrimination with liquid scintillators. This work was carried out with a neutron sensitive liquid scintillator, EJ-301, with signals digitized at 3.2 GHz with 12 bits of resolution utilizing a CAEN DT-5743 digitizer. Measurements were artificially reduced in sampling depth and frequency to investigate the importance of these parameters for performance of the machine learning algorithms. Two isotopic neutron source, PuBe and AmBe, and three photon sources: Na, Co, and Cs were used for generation of the training and validation sets as well as for energy calibration. The greatest performance was achieved with a lightly altered implementation of GoogLeNet and with the full sampling rate and bit depth afforded by the digitizer. A true positive rate of 69.17 % was achieved while correctly rejecting 99.9999 % of photon events. This performance ranges from 1.30 % at events greater than 3 MeVee to 89.96 % between 340-1000 keVee. For neutron events with energy below 200 keVee 21.48 % of the validation neutrons are still identified as neutrons.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.apradiso.2024.111384DOI Listing

Publication Analysis

Top Keywords

machine learning
12
pulse shape
8
shape discrimination
8
performance machine
8
neutralnet development
4
development testing
4
testing machine
4
learning solution
4
solution pulse
4
discrimination accurate
4

Similar Publications

Objective: The first objective is to develop a nuchal thickness reference chart. The second objective is to compare rule-based algorithms and machine learning models in predicting small-for-gestational-age infants.

Method: This retrospective study involved singleton pregnancies at University Malaya Medical Centre, Malaysia, developed a nuchal thickness chart and evaluated its predictive value for small-for-gestational-age using Malaysian and Singapore cohorts.

View Article and Find Full Text PDF

Radiography is a field of medicine inherently intertwined with technology. The dependency on technology is very high for obtaining images in ultrasound (US), computed tomography (CT), and magnetic resonance imaging (MRI). Although the reduction in radiation dose is not applicable in US and MRI, advancements in technology have made it possible in CT, with ongoing studies aimed at further optimization.

View Article and Find Full Text PDF

Purpose: Patients with advanced non-small cell lung cancer (NSCLC) have varying responses to immunotherapy, but there are no reliable, accepted biomarkers to accurately predict its therapeutic efficacy. The present study aimed to construct individualized models through automatic machine learning (autoML) to predict the efficacy of immunotherapy in patients with inoperable advanced NSCLC.

Methods: A total of 63 eligible participants were included and randomized into training and validation groups.

View Article and Find Full Text PDF

Plastic waste management is one of the key issues in global environmental protection. Integrating spectroscopy acquisition devices with deep learning algorithms has emerged as an effective method for rapid plastic classification. However, the challenges in collecting plastic samples and spectroscopy data have resulted in a limited number of data samples and an incomplete comparison of relevant classification algorithms.

View Article and Find Full Text PDF

Background And Aim: Discriminating between idiosyncratic drug-induced liver injury (DILI) and autoimmune hepatitis (AIH) is critical yet challenging. We aim to develop and validate a machine learning (ML)-based model to aid in this differentiation.

Methods: This multicenter cohort study utilised a development set from Beijing Friendship Hospital, with retrospective and prospective validation sets from 10 tertiary hospitals across various regions of China spanning January 2009 to May 2023.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!