1. A historical revue of seton operations is presented, which were actually explored for the first time by Rollet in 1907. 2. The paramount importance of the selection of the appropriate material for the setons is stressed. 3. Ocular tolerance especially of silicone tubings has been investigated by animal experiments. Excellent tolerance of silicone intraocularly as well as subconjunctivally has been found. This fact confirms experimental investigations by other authors. 4. In animal experiments for the first time a surgical technique securing firm anchorage of a sole silicone tubing could be developed. Insertion of a silicone catheter was combined with thermal sclerostomy; ocular hypotony was not encountered. 5. A study exploring aqueous egress following the new surgical procedure has been conducted by means of injection of fluorescein into the anterior chamber. Various exit-sites of aqueous were recorded: diffuse outflow through the filtration cleft as well as the catheter lumen, and also via channels either within lymph vessels or secondary aqueous veins. 6. Aqueous outflow following the seton operation has also been studied by scintigraphic means; the first description of this method in glaucoma-operated eyes is presented. Applying this technique not only the existence of a filtering bleb is documented, but in addition the speed of aqueous transit through the filtering bleb was measured. This transit has been found to be a rapid one. 7. The clinical results of this type of seton operation do confirm the experimental evidence of excellent ocular tolerance of silicone tubings as well as the reliability of their firm anchorage. Postoperative tension with or without additional antiglaucomatous medication proved quite satisfactory. 8. The proposed surgical procedure is recommendable especially in patients exhibiting haemorrhagic glaucoma, were conventional methods are likely to fail in the majority of cases.
Download full-text PDF |
Source |
---|
The kinetically-derived maximal dose (KMD) is defined as the maximum external dose at which kinetics are unchanged relative to lower doses, e.g., doses at which kinetic processes are not saturated.
View Article and Find Full Text PDFACS Appl Mater Interfaces
January 2025
State Key Laboratory of Pulp and Paper Engineering, School of Light Industry and Engineering, South China University of Technology, Guangzhou 510641, People's Republic of China.
The advancement of underwater monitoring technologies has been significantly hampered by the limitations of traditional electrical sensors, particularly in the presence of electromagnetic interference and safety concerns in aquatic environments. Fiber optic sensors are therefore nowadays widely applied to underwater monitoring devices. However, silicon- and polymer-based optical fibers often face challenges, such as rigidity, susceptibility to environmental stress, and limited operational flexibility.
View Article and Find Full Text PDFFront Vet Sci
December 2024
Ceva Santé Animale, Libourne, France.
The aim of this study is to assess a pheromone complex-impregnated collar in the control of feline problem behaviors, and to assess the ease of use and tolerance of the collar compared with a regular collar. Six hundred and twenty-four cats from 459 households with one or more of four problem behaviors (problem urination, scratching, fear, or inter-cat conflict) were recruited to a 28-day study. Households were randomly assigned so that each cat received either a pheromone-impregnated polymer collar (containing 13% FELIWAY Optimum) or a control regular silicone collar.
View Article and Find Full Text PDFEJNMMI Radiopharm Chem
December 2024
Department of Medicinal Chemistry, College of Pharmacy, University of Michigan, Ann Arbor, MI, 48109, USA.
Background: Approval of Locametz and Illuccix kits for the manufacture of [Ga]Ga-PSMA-11 (gallium Ga68 gozetotide), a PET imaging agent for prostate cancer, as well as the corresponding therapeutic ([Lu]Lu-PSMA-617 Pluvicto), has led to a rapid increase in demand for [Ga]Ga-PSMA-11 PET imaging. Radiopharmaceutical manufacturers, using Ge/Ga generators, may decide to adopt Locametz and/or Illuccix kits, which requires a comparison to select the most suitable kit for day-to-day use. The objective of this article is to compare both kits and provide guidance for selecting one for routine use, as well as evaluate labeling consistency of both kits during routine production.
View Article and Find Full Text PDFCan Prosthet Orthot J
June 2024
Department of Medicine, Faculty of Medicine, University of Ottawa, Ottawa, Canada.
Background: While waiting to receive a prosthesis, individuals with amputations could benefit from using a temporary training prosthesis to expedite the rehabilitation process and prepare them for subsequent walking with their prosthesis.
Objectives: To design and build a temporary training prosthesis for people with a transtibial amputation.
Methodology: Various temporary training prostheses were designed and simulated using SolidWorks software, followed by fabricating and testing multiple prototypes.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!