Study Objective: Acute aortic syndrome is a life-threatening emergency condition. Previous systematic reviews of D-dimer diagnostic accuracy for acute aortic syndrome have been contradictory and based on limited data, but recently published studies offer potential for a more definitive overview. We aimed to perform a systematic review and meta-analysis to determine the diagnostic accuracy of D-dimer for diagnosing acute aortic syndrome.

Methods: We searched MEDLINE, EMBASE, and the Cochrane Library from inception to February 2024. Additionally, the reference lists of included studies and other systematic reviews were thoroughly searched. All diagnostic cohort studies (prospective or retrospective) that assessed the use of D-dimer for diagnosing acute aortic syndrome compared with a reference standard test (eg, computed tomographic angiography (CTA), ECG-gated CTA, echocardiography, magnetic resonance angiography, operation, or autopsy) were included. Two independent reviewers completed study selection, data extractions and quality assessment using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool. Data were synthesized using a bivariate meta-analysis model.

Results: Of 2017 potentially relevant citations, 25 cohort studies met the inclusion criteria, and 18 reporting the 500 ng/mL threshold were included in the primary meta-analysis. Risk of bias domains were mostly unclear due to limited study reporting. The summary sensitivity was 96.5% (95% credible interval [CrI] 94.8% to 98%) and summary specificity was 56.2% (95% CrI, 48.3% to 63.9%). Study specificity varied markedly from 33% to 86%, indicating substantial heterogeneity. Sensitivity analysis including the 7 studies reporting other thresholds showed summary sensitivity of 95.7% (95% CrI, 93.2% to 97.5%) and summary specificity of 57.5% (95% CrI, 50.1% to 64.6%).

Conclusion: D-dimer concentration has high sensitivity (96.5%) and moderate specificity (56.2%) for acute aortic syndrome, with some uncertainty around estimates due to risk of bias and heterogeneity. Previous meta-analysis reporting higher specificity may be explained by inclusion of case-control studies that may overestimate accuracy.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.annemergmed.2024.05.001DOI Listing

Publication Analysis

Top Keywords

acute aortic
24
diagnostic accuracy
16
aortic syndrome
16
95% cri
12
accuracy d-dimer
8
systematic review
8
review meta-analysis
8
systematic reviews
8
d-dimer diagnosing
8
diagnosing acute
8

Similar Publications

Acute Decompensated Valvular Disease in the Intensive Care Unit.

JACC Adv

December 2024

TIMI Study Group, Cardiovascular Division, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, USA.

Acute decompensated valvular disease encompasses a group of complex and challenging conditions, which are often the primary reason for admission to the cardiac intensive care unit and can also complicate the management of other primary cardiac disorders. Critically ill patients with valvular disease also present unique diagnostic and management challenges. Historically, medical and percutaneous interventional therapies have been limited and surgery was the only definitive treatment; however, surgical risk can at times be prohibitive.

View Article and Find Full Text PDF

The patient an 85-year-old female resided in a care facility where she maintained an independent daily activity level. She was discovered hunched over a table in her room, displaying reduced responsiveness and prompting an emergency call. Initially, her blood pressure was within 60 mmHg, and she was transported by ambulance to our hospital.

View Article and Find Full Text PDF

The outcomes of cardiac surgery in patients with hematologic disorders are significantly worse. However, details of the clinical course of each hematologic disease remain unclear. Myelodysplastic syndrome (MDS) presents with progressive pancytopenia that has the risk of infection, hemorrhage, and transformation to acute myelogenous leukemia.

View Article and Find Full Text PDF

In surgery for acute type A aortic dissection, controlling bleeding from the posterior wall of the proximal anastomosis is particularly challenging. To address this, we use the "reversed turn-up technique." For the reinforcement of the proximal aortic stump, Teflon felt strips were placed inside and outside the suture line with 4-0 polypropylene continuous transverse mattress sutures, and BioGlue was applied to the false lumen.

View Article and Find Full Text PDF

Survival after surgery for acute type A aortic dissection in octogenarians.

J Geriatr Cardiol

November 2024

Department of Cardiovascular Surgery, Centro Cardiologico Monzino IRCCS, Milan, Italy.

Objective: To evaluate the benefits of surgical repair acute type A aortic dissection (ATAAD) on survival of octogenarians.

Methods: Patients who underwent surgery for acute ATAAD from the multicenter European Registry of Type A Aortic Dissection (ERTAAD) were the subjects of the present analysis.

Results: 326 (8.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!