Background And Purpose: International variation exists in the types of shoulder replacement used for treatment of specific diseases. Implant choice continues to evolve without high-quality evidence. Our aim was to evaluate trends in incidence rates of shoulder replacement and assess any recent changes in practice between countries by using registry data.
Methods: Patient characteristics, indication and year of surgery, type of replacement, and collection methods of patient-reported outcomes (PROMs) was extracted from 11 public joint registries. Meta-analyses examined use of reverse total shoulder replacement (RTSR) for osteoarthritis, cuff tear arthropathy, and acute fracture; use of anatomical total shoulder replacement (TSR) for osteoarthritis; and use of humeral hemiarthroplasty for fracture.
Results: The annual growth rate of shoulder replacements performed is 6-15% (2011-2019). The use of RTSR has almost doubled (93%). RTSR is now universally performed for cuff tear arthropathy (97.3%, 95% confidence interval [CI] 96.0-98.1). Its use for avascular necrosis, trauma, and inflammatory arthropathy is increasing. The use of RTSR was similar (43.1%, CI 30.0-57.2) versus TSR (44.7%, CI 31.1-59.1) for osteoarthritis. The types of PROMs used, collection time points, and response rates lack standardization. COVID-19 had a varying inter-registry impact on incidence rates.
Conclusion: The incidence of shoulder replacements has grown. Use of RTSR has increased for all disease indications despite limited high-quality evidence driving this change in indications outside of cuff arthropathy. Consequently, less variation is observed in international practice. Existing differences now relate to use of newer implant types and methodology of PROMs collection, which prevents international comparison and outcome analysis.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11184711 | PMC |
http://dx.doi.org/10.2340/17453674.2024.40948 | DOI Listing |
Front Bioeng Biotechnol
December 2024
Center for Healthcare Robotics, Korea Institute of Science and Technology, Seoul, Republic of Korea.
Introduction: During tasks like minimally invasive surgery (MIS), various factors can make working environment not be ergonomic, and those situations will accumulate fatigue in the surgeon's muscles which will inevitably lead to poor surgical performance. Therefore, there has been a need for technical solutions to solve this problem and one of the methods is exoskeleton robots.
Methods: We designed a passive shoulder exoskeleton whose workspace could be used for MIS to assist the surgeon's movements and performed computational and clinical validation.
Eur J Orthop Surg Traumatol
December 2024
Department of Orthopaedic Surgery, Royal North Shore Hospital, St Leonards, Australia.
Background: Proximal humerus fractures (PHF) are common with approximately 30% requiring surgical intervention. This ranges from open reduction internal fixation (ORIF) to shoulder arthroplasty (including hemiarthroplasty, total shoulder arthroplasty (TSA), reverse total shoulder arthroplasty (RTSA)). The aim of this study was to assess trends in operative interventions for PHF in an Australian population.
View Article and Find Full Text PDFShoulder Elbow
December 2024
Specialty Orthopaedic Upper Limbs Surgery Research Foundation, Bella Vista, NSW, Australia.
Background: This study aimed to determine the revision outcome between a centrally fixed stemless anatomic design and other total anatomic shoulder replacements using data from a large national arthroplasty registry.
Methods: The study period was from December 2011 to December 2022 and included three cohorts; primary Affinis stemless anatomic (AFS), all other primary total stemless anatomic (sTSA) and primary total stemmed anatomic shoulder arthroplasty (aTSA). The endpoint was all-cause revision using cumulative percent revision (CPR).
PLoS One
December 2024
Department of Orthopedics and Traumatology, Turku University Hospital, Turku, Finland.
Background: This study aims to report and analyze disease-specific patient-reported outcome measure (PROM) effect size (ES) variations, in patients undergoing major arthroplasty surgery.
Material And Methods: All institution-based data of primary knee, hip, or shoulder arthroplasty patients at Turku University hospital (Finland) between January 2020 -December 2022 were collected, and treatment outcome assessed as a PROM difference between baseline and one-year follow-up. PROM ES were calculated for each patient and patient group separately, and patients with ES >0.
Rev Bras Ortop (Sao Paulo)
December 2024
Divisão de Ensino e Pesquisa, Instituto Nacional de Traumatologia e Ortopedia Jamil Haddad, Rio de Janeiro, RJ, Brasil.
To evaluate the intra and intersurgeon variability regarding the positioning and selection of implants in reverse shoulder arthroplasty. A cross-sectional study assessed computed tomography images of the shoulder joint of patients diagnosed with degenerative joint diseases. The study team included seven specialists in shoulder surgery, representing six different institutions.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!