Purpose: Although active spot scanning irradiation technique is theoretically superior to passive-scattered broad beam irradiation with respect to normal tissue sparing, corroborations of the clinical benefit of carbon-ion spot scanning have remained scarce. This study aims to investigate the feasibility and clinical implementation of an active spot scanning beam calculation algorithm in a homemade carbon-ion treatment planning system by comparing it with a conventional passive uniform scanning technique.

Methods And Materials: Carbon-ion plans were initially formulated using spot/uniform scanning methods in 22 participants enrolled in a prospective observational clinical trial. Subsequently, 2 additional plans were designed, resulting in 3 carbon-ion plans for each participant: uniform and spot scanning with miniridge filters of 2 mm and 4 mm, respectively.

Results: The findings revealed no significant differences in dose homogeneity; however, significant differences in dose conformity were found between the active and passive scanning plans. For dose drop-off outside the target volume, the average gradient index values were 1.94 (95% CI, 1.79%-2.09%), 1.87 (95% CI, 1.73%-2.01%), and 3.20 (95% CI, 2.80%-3.61%) for the miniridge filters of 2 mm and 4 mm, and uniform scanning plans, respectively. The pretreatment tumor volume was 124.7 cm (range, 54.2-234 cm), and the average shrinkage observed was 38.4% (95% CI, 17.6%-59.4%). Seven participants experienced grade 1 acute toxicity, and 4 experienced grade 2 acute toxicity. However, none of the patients developed grade 3 acute toxicity.

Conclusions: Increasing evidence suggests that potential clinical advantages of spot scanning delivery underlie its technical characteristics. As one among the few institutions currently using carbon-ion radiation therapy, the investigation also provides promising safety and efficacy outcomes from the initial groups of treated participants, thereby contributing to the established clinical evidence supporting the effectiveness and superiority of carbon-ion therapy.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11177064PMC
http://dx.doi.org/10.1016/j.adro.2024.101503DOI Listing

Publication Analysis

Top Keywords

spot scanning
24
active spot
12
grade acute
12
scanning
10
scanning beam
8
carbon-ion treatment
8
treatment planning
8
planning system
8
uniform scanning
8
carbon-ion plans
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!