A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 144

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 144
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 212
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1002
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3142
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Development and Safety Trial of the OstreaVent2™ Prototype for Mechanically Ventilated Adult Patients. | LitMetric

Background: With the surge of COVID-19 infections, there were concerns about shortage of mechanical ventilator in several countries including the Philippines.

Objective: To transform a locally made, low-cost, neonatal ventilator into a volume- and pressure-controlled, adult ventilator and to determine its safe use among ventilated, adult patients at the Philippine General Hospital.

Methods: The modification of the neonatal ventilator (OstreaVent1) to the adult OstreaVent2 was based on the critical need for adult ventilators, in volume or pressure mode, in the Philippines due to the COVID-19 pandemic. The adult ventilator settings were calibrated and tested for two days to check for consistency and tolerance and then submitted to a third party for certification. Once certified, a safety trial of 10 stable adult patients on mechanical ventilator was conducted. The patients were placed on the OstreaVent2 for four hours while ventilator parameters, patient's vital signs, and arterial blood gases were monitored at baseline, during, and after placement on the OstreaVent2. A post-study chest radiograph was also done to rule out pulmonary complications, particularly atelectasis and pneumothorax.

Results: The prototype OstreaVent2 received an FDA Certification for Medical Listing after passing its third-party certification. Ten patients (60% male) recruited in the study had a mean age of 39.1 ± 11.6 years. Half of the patients had a diagnosis of non-COVID-19 pneumonia. During the 4-hour study period, the patients while on the OstreaVent2, had stable ventilator settings and most of the variabilities were within the acceptable tolerances. Vital signs were stable and arterial blood gases were within normal limits. One patient developed alar flaring which was relieved by endotracheal tube suctioning. No patient was withdrawn from the study. One patient who was already transferred out of the ICU subsequently deteriorated and died three days after transfer to the stepdown unit from a non-ventilator related cause.

Conclusion: The new OstreaVent2 is safe to use among adults who need ventilator support. Variabilities in the ventilator's performance were within acceptable tolerances. Clinical and blood gas measurements of the patients were stable while on the ventilator.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11168947PMC
http://dx.doi.org/10.47895/amp.v58i7.8329DOI Listing

Publication Analysis

Top Keywords

adult patients
12
ventilator
10
safety trial
8
ventilated adult
8
patients
8
mechanical ventilator
8
neonatal ventilator
8
adult ventilator
8
ventilator settings
8
patients ostreavent2
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!