Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: To evaluate the divergence between the neodymium-doped yttrium aluminum garnet (Nd:YAG) surgical laser and the aiming diode laser beams foci.
Design: Optical analysis and measurements were performed using a Volk Goldmann 3-mirror lens with a Nidek YC-1800 Nd:YAG laser apparatus.
Subjects: None.
Methods: We used the Zemax OpticStudio program for the model of Nd:YAG treatment in a human eye. Additionally, theoretical calculations were performed.
Main Outcome Measures: The divergence between the Nd:YAG laser focus and the intersection of the 2 aiming beams inside the eye.
Results: Focal points of the 2 laser beams converge 8 mm behind the cornea. Posterior to this point, the intersection of the diode laser aiming beams lies in front of the focal point of the Nd:YAG treatment laser, with distance between the 2 foci progressively increasing up to 305 microns at 24 mm behind the cornea.
Conclusions: We report the degree of divergence between the 2 lasers' focal points due to the difference in refraction between the corresponding wavelengths. These results have high practical relevance, as they provide a starting point for increasing the accuracy of Nd:YAG laser treatment, particularly when applied to the posterior segment, thereby minimizing the risk of complications. Current Nd:YAG laser devices have the built-in ability to modify the focal point of the aiming beam along the -axis, thus providing possibility for an immediate application of our findings in clinical practice.
Financial Disclosures: The authors have no proprietary or commercial interest in any materials discussed in this article.