A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Advanced Optical Analysis of Divergence Between the Foci of the Neodymium-Doped Yttrium Aluminum Garnet (Nd:YAG) and Aiming Beam Lasers. | LitMetric

Purpose: To evaluate the divergence between the neodymium-doped yttrium aluminum garnet (Nd:YAG) surgical laser and the aiming diode laser beams foci.

Design: Optical analysis and measurements were performed using a Volk Goldmann 3-mirror lens with a Nidek YC-1800 Nd:YAG laser apparatus.

Subjects: None.

Methods: We used the Zemax OpticStudio program for the model of Nd:YAG treatment in a human eye. Additionally, theoretical calculations were performed.

Main Outcome Measures: The divergence between the Nd:YAG laser focus and the intersection of the 2 aiming beams inside the eye.

Results: Focal points of the 2 laser beams converge 8 mm behind the cornea. Posterior to this point, the intersection of the diode laser aiming beams lies in front of the focal point of the Nd:YAG treatment laser, with distance between the 2 foci progressively increasing up to 305 microns at 24 mm behind the cornea.

Conclusions: We report the degree of divergence between the 2 lasers' focal points due to the difference in refraction between the corresponding wavelengths. These results have high practical relevance, as they provide a starting point for increasing the accuracy of Nd:YAG laser treatment, particularly when applied to the posterior segment, thereby minimizing the risk of complications. Current Nd:YAG laser devices have the built-in ability to modify the focal point of the aiming beam along the -axis, thus providing possibility for an immediate application of our findings in clinical practice.

Financial Disclosures: The authors have no proprietary or commercial interest in any materials discussed in this article.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11179403PMC
http://dx.doi.org/10.1016/j.xops.2024.100512DOI Listing

Publication Analysis

Top Keywords

ndyag laser
16
laser
9
optical analysis
8
neodymium-doped yttrium
8
yttrium aluminum
8
aluminum garnet
8
ndyag
8
garnet ndyag
8
aiming beam
8
laser aiming
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!