Statement Of Problem: High-level evidence regarding the accuracy and adaptation of 1-piece endodontic crowns fabricated by using 3-dimensional (3D) printing technology is lacking.
Purpose: The purpose of this in vitro study was to compare the accuracy and adaptation of 1-piece endodontic crowns produced through 3D printing and computer-numerical-control milling technology and to explore the influence of trueness on 1-piece endodontic crown adaptation.
Material And Methods: One-piece endodontic crowns were prepared for a typodont right mandibular first molar, scanned with a 3Shape E3 scanner, and designed with a computer-aided design software program. Two types of 1-piece endodontic crowns were fabricated: 3D printed by using resin and zirconia slurry and milled from Grandio and zirconia blocks. A reverse engineering software program was used to superimpose 4 groups of crowns with the reference crowns used for accuracy analysis. Microcomputed tomography was used to measure 1-piece endodontic crown adaptation. The correlation between trueness and adaptation was evaluated through the Spearman correlation test (α=.05).
Results: Milled resin-based 1-piece endodontic crowns demonstrated better trueness on marginal and occlusal surfaces compared with 3D printed ones (P<.001). However, no significant difference was observed in the trueness of intaglio surfaces between the 2 groups (P>.05). The milled group exhibited better adaptations than the printed one (P<.05). For zirconia 1-piece endodontic crowns, no significant differences were found in trueness or adaptation between the milled and printed groups (P>.05). Notably, the trueness of the axial wall had the greatest impact on overall crown adaptation, with its adaptation closely linked to the trueness of each area, particularly the axial wall.
Conclusions: Milled resin-based 1-piece endodontic crowns exhibited higher levels of trueness and adaptation compared with 3D printed ones, while 3D printed zirconia 1-piece endodontic crowns were comparable with milled ones.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.prosdent.2024.05.011 | DOI Listing |
BMC Oral Health
January 2025
Department of Endodontics, School of Dentistry, Shahid Sadoughi University of Medical Sciences, Yazd, Iran.
Objectives: This study aimed to compare the marginal adaptation of a cold ceramic (CC) sealer with the single-cone obturation technique with that of an AH-26 sealer with the lateral compaction technique in single-canal teeth.
Materials And Methods: In this in vitro experimental study, the root canals of 24 extracted single-rooted single-canal teeth were instrumented to F3 files by the crown-down technique and randomly assigned to 2 groups (n = 12). The root canals were obturated with a CC sealer and single-cone obturation technique with 4% gutta-percha in group 1 and with an AH-26 sealer and lateral compaction technique with 2% gutta-percha in group 2.
J Endod
January 2025
Department of Endodontics, Texas A&M College of Dentistry, 3302 Gaston Ave, Dallas, TX 75246. Electronic address:
Introduction: Endodontic access is often one of the most challenging aspects of treatment, particularly in cases involving locating calcified or missed canals, or when performing selective retreatments of a targeted root. Therefore, the purpose of this study is to compare the accuracy of targeted accesses made using prefabricated grid to those made using freehand techniques with CBCT measurements METHODS: Twenty extracted maxillary molars were mounted into the TrueJaw maxillary model (PlanB Dental, CA). To replicate a clinical scenario where the tooth is extensively restored or has a calcified pulp chamber, the build-up material was intentionally placed directly over the canal orifices.
View Article and Find Full Text PDFInt J Dent
January 2025
Department of Conservative Dentistry and Endodontics, Bangabandhu Sheikh Mujib Medical University, Dhaka, Bangladesh.
Due to the presence of ion reservoir, saliva may facilitate enamel remineralization and neutralize pH of acidic beverage leads to prevent enamel demineralization. Saliva substitute/artificial saliva has been developed in subsequent years and may differ in physical properties, function, or pH level from 5.0 to 7.
View Article and Find Full Text PDFBMC Oral Health
January 2025
Associate Professor of Operative Dentistry, Conservative Dentistry Department, Faculty of Oral and Dental Medicine Badr University in Cairo, Cairo, Egypt.
Background: Endodontic treatment aims in the preservation of extremely carious primary teeth. For root canal therapy to be successful, root canals must be properly prepared and effectively irrigated .Therefore, it is necessary to select the proper root canal disinfection method to preserve the primary tooth.
View Article and Find Full Text PDFJ Indian Soc Pedod Prev Dent
October 2024
Department of Pediatric and Preventive Dentistry, Subharti Dental College and Hospital, Swami Vivekanand Subharti University, Meerut, Uttar Pradesh, India.
Background And Aim: This study aims to evaluate the efficacy of different endodontic irrigants employed in the lesion sterilization and tissue repair (LSTR) technique.
Methods: Forty children aged 4-8 years having at least one primary molar with irreversible pulpitis/pulpal necrosis indicated for pulpectomy were included. Participants were randomly divided into three test groups (Group A, B, and C) and one control group (Group D).
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!