Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 143
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 143
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 209
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3098
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Severity: Warning
Message: Attempt to read property "Count" on bool
Filename: helpers/my_audit_helper.php
Line Number: 3100
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3100
Function: _error_handler
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Divergence between intra-arterial catheters blood pressure (ABP) and noninvasive oscillometry (NIBP) may affect the care of children with brain arteriovenous malformations (bAVMs). We described the agreement between ABP and NIBP in these children.
Methods: We conducted a retrospective review of patients admitted to the pediatric intensive care unit between 2017 and 2023 with bAVM rupture. Paired ABP and NIBP measurements were collected. Bland-Altman analyses were used to assess agreement. Correlation analysis was conducted between higher ABP and divergence between systolic BP (SBP) measurements. Hypertension was defined as mean arterial pressure (MAP) exceeding age-based 95th percentile.
Results: Thirty-four patients with 1901 BP pairs were observed. Bias overall was acceptable, but standard deviation (SD) was high. The best agreement of MAP was in non-hypertensive (bias 1.23 mmHg, SD 8.03 mmHg) and radial arterial catheters (bias 1.83 mmHg, SD 9.08 mmHg) subgroups. Bias for SBP was higher in hypertension (10.98 mmHg) and in infratentorial bAVMs (7.42 mmHg), suggesting poorer agreement in these subgroups. There were significant correlations between intra-arterial MAP and SBP divergence (R = +0.346, p<.001) and between intra-arterial SBP and SBP divergence (R = +0.677, p<.001), suggesting divergence widens with higher BP. Around 25 % of measurement pairs diverged to where one measurement crossed the clinical threshold for treatment, while the other did not, with ABP being more frequently higher than NIBP.
Conclusions: There is good agreement between ABP and NIBP, particularly in non-hypertensive ranges and with radial arterial catheters. Measurements, however, diverge in hypertension. Further research must define age-based thresholds, validate methods of BP measurement, and determine the effect of BP reduction on outcomes in these children.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.clineuro.2024.108363 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!