Objectives: Lateral compression type II pelvic ring injuries can be treated with fixation through open or percutaneous approaches depending on the injury pattern and available osseous fixation pathways. The start site of iliosacral screws to stabilize these injuries should be on the unstable posterior iliac fragment; however, our understanding of start sites for iliosacral screws has not been developed. The purpose of this study is to provide an analysis of iliosacral screw start sites on the posterior ilium to help guide treatment of pelvic ring injuries.

Methods: One-hundred and seventeen consecutive patients at an academic level I trauma center with pelvic ring injuries who underwent surgical treatment with iliosacral screws were included in the final analysis. The start sites of iliosacral screws with confirmed intraosseous placement on a postoperative computed tomography were mapped on the posterior ilium and analyzed according to the sacral segment and type of iliosacral screw.

Results: One-hundred and seventeen patients were included in the final analysis. Of the total of 272 iliosacral screw insertion sites analyzed, 145 (53%) were sacroiliac-style screws and 127 (47%) were transsacral screws. The insertion sites for sacroiliac-style screws and transsacral screws at different sacral segment levels can vary but have predictable regions on the posterior ilium relative to reliable osseous landmarks.

Conclusions: Iliosacral screws start sites on the posterior ilium have reliable regions that can be used to plan posterior fixation of pelvic ring injuries.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.injury.2024.111655DOI Listing

Publication Analysis

Top Keywords

iliosacral screws
24
posterior ilium
20
pelvic ring
16
start sites
16
insertion sites
12
sites iliosacral
12
ring injuries
12
screws
10
iliosacral
9
posterior
8

Similar Publications

Objective: Type IV fragility fractures of pelvis (FFP IV) are serious and complicated and the treatment is challengeable. Robotic-assisted minimally invasive triangular fixation (RoboTFX) is a new and advanced technique to treat this injury. The objective of this report is to evaluate the clinical outcomes of FFP IV treated with RoboTFX.

View Article and Find Full Text PDF
Article Synopsis
  • Fragility pelvic fractures are becoming more common due to increased life expectancy, often requiring surgery with ilio-sacral screws for stabilization.* -
  • This review discusses a novel, low-cost cement augmentation technique for ilio-sacral screws, designed for patients with poor bone quality and includes case examples from five patients treated between 2017 and 2024.* -
  • The new surgical method is straightforward and uses readily available instruments, but further research is needed to prove its efficacy compared to traditional techniques without cement augmentation.*
View Article and Find Full Text PDF

Objective: Considering the high incidence and complexity of unstable posterior pelvic ring fractures, and the need for less invasive and more effective treatment options, this study aims to introduce a novel minimally invasive, safe, and simple internal fixation method for the treatment of unstable posterior pelvic ring fractures using the sacroiliac joint locking plate (SJP) system, and to provide biomechanical validation and clinical evaluation of this method.

Methods: Biomechanical research was conducted using standard pelvic bone models from Synbone, Switzerland, to create Denis II zone unstable posterior pelvic ring fracture models, and to assess the stability of the SJP under different loads compared with traditional fixation methods. A retrospective clinical study analyzed the clinical efficacy of SJP treatment in 62 patients (mean age of 51.

View Article and Find Full Text PDF

Treatment options for unstable posterior pelvic ring lesions: A multicenter retrospective cohort study of the Italian Society for the Traumatology of the Pelvis.

Injury

September 2024

Orthopedics and Traumatology Unit, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Rome, Italy; Department of Orthopedics and Traumatology, Università Cattolica del Sacro Cuore, Rome, Italy. Electronic address:

Purpose: Posterior pelvic ring lesions are a common finding in patients with pelvic trauma, representing a challenging condition for trauma surgeons. Surgical options are different and there is not yet evidence about the best option. Aim of the study are: (i) to compare Lumbopelvic fixation (LPF) and ilio-sacral screw fixation (ISS) regarding clinical and radiological outcome in unstable posterior pelvic ring injuries, both as whole population and single similar fracture types according to Tile classification (C1vsC1, C2vsC2, C3vsC3); (ii) to analyze clinical outcomes and complications in lumbopelvic fixation group, comparing open and closed reduction technique.

View Article and Find Full Text PDF

Operative treatment of fragility fractures of the pelvis has become a gold standard. Preoperative planning, including the assessment of the pathway for iliosacral screws, is crucial. The anchorage of the screw depends on the bone quality.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!