This study aims to examine the validity and reliability of the UltraScan650™, a portable ultrasound device, used to measure BMD at the 1/3rd radius position. Fifty-two female first responders and healthcare providers were assessed using DXA (forearm, femur, lumbar, and total body) and the UltraScan650™. Fat and lean mass were also assessed using the DXA. Pearson correlations, Bland-Altman plots, t-tests, and linear regressions were used to assess validity. Intra-class correlation (ICC) coefficients were used to assess reliability. Inter-rater reliability and repeatability were good (ICC = 0.896 [0.818; 0.942], p < 0.001) and excellent (ICC = 0.917 [0.785; 0.989], p < 0.001), respectively. BMD as measured by the UltraScan650™ was weakly correlated to the DXA (r = 0.382 [0.121; 0.593], p = 0.0052). Bland-Altman plots revealed that the UltraScan650™ underestimated BMD (-0.0569 g/cm), this was confirmed with a significant paired t-test (p < 0.001). A linear regression was performed (0.4744 × UltraScan650™ + 0.4170) to provide more information as to the issue of agreement. Bland-Altman plots revealed a negligible bias, supported by a paired t-test (p = 0.9978). Pearson's correlation revealed a significant relationship (r = -0.771 [-0.862; -0.631], p < 0.0001) between adjusted UltraScan650™-DXA and the average of the two scans (i.e., adjusted UltraScan650™ and DXA), suggesting a proportional constant error and proportional constant variability in measurements of BMD from the UltraScan650™. The UltraScan650™ is not a valid alternative to DXA for diagnostic purposes; however, the UltraScan650™ could be used as a screening tool in the clinical and research setting given the linear transformation is employed.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/ca.24187 | DOI Listing |
Front Biosci (Landmark Ed)
January 2025
Department of Oral and Maxillofacial Surgery, The First Affiliated Hospital of Fujian Medical University, Fujian Provincial Key Laboratory of Stomatology, National Regional Medical Center, Binhai Campus of The First Affiliated Hospital, 350005 Fuzhou, Fujian, China.
Background: In this study, we prepared a porous gradient scaffold with hydroxyapatite microtubules (HAMT) and chitosan (CHS) and investigated osteogenesis induced by these scaffolds.
Methods: The arrangement of wax balls in the mold can control the size and distribution of the pores of the scaffold, and form an interconnected gradient pore structure. The scaffolds were systematically evaluated and for biocompatibility, biological activity, and regulatory mechanisms.
J Integr Neurosci
January 2025
Department of Physical Therapy, Hangzhou Geriatric Hospital, 310022 Hangzhou, Zhejiang, China.
Background: Observation, execution, and imitation of target actions based on mirror neuron network (MNN) have become common physiotherapy strategies. Electrical stimulation (ES) is a common intervention to improve muscle strength and motor control in rehabilitation treatments. It is possible to enhance MNN's activation by combining motor execution (ME) and motor imitation (MI) with ES simultaneously.
View Article and Find Full Text PDFJ Investig Med High Impact Case Rep
January 2025
LSU Health Shreveport, LA, USA.
An 18-year-old teenager with significant atherosclerotic cardiovascular disease (ASCVD) risk factors developed acute chest pain. His electrocardiogram showed inferior ST-segment elevations. Emergent coronary angiogram revealed complete thrombotic occlusion of the right coronary artery.
View Article and Find Full Text PDFSensors (Basel)
January 2025
School of Biomedical Engineering and Imaging Sciences, King's College London, London SE1 7EH, UK.
Ultrasound imaging is widely valued for its safety, non-invasiveness, and real-time capabilities but is often limited by operator variability, affecting image quality and reproducibility. Robot-assisted ultrasound may provide a solution by delivering more consistent, precise, and faster scans, potentially reducing human error and healthcare costs. Effective force control is crucial in robotic ultrasound scanning to ensure consistent image quality and patient safety.
View Article and Find Full Text PDFJ Clin Med
January 2025
Joyce and Irving Goldman Medical School, Faculty of Health Sciences, Ben-Gurion University of the Negev, Beer-Sheva 8410501, Israel.
: Home rehabilitation improves patient satisfaction and reduces the need for specialist consultations. Hemodialysis is a costly post-ICU service that requires frequent monitoring. Previous studies have demonstrated the feasibility and accuracy of patients self-scanning their lungs with an ultrasound device within the hospital.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!