A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Fetal bradycardia in open versus fetoscopic prenatal repair of spina bifida. | LitMetric

Fetal bradycardia in open versus fetoscopic prenatal repair of spina bifida.

Prenat Diagn

Department of Surgery, The Chicago Institute for Fetal Health, Ann and Robert H. Lurie Children's Hospital of Chicago, Northwestern University Feinberg School of Medicine, Chicago, Illinois, USA.

Published: August 2024

Objective: To compare the occurrence of fetal bradycardia in open versus fetoscopic fetal spina bifida surgery.

Methods: This is a single-institution retrospective cohort study of patients undergoing open (n = 25) or fetoscopic (n = 26) spina bifida repair between 2017 and 2022. From October 2017 to June 2020, spina bifida repairs were performed via an open classical hysterotomy, and from November 2020 to June 2022 fetoscopic repairs were performed following transition to this technique. Fetal heart rate (FHR) in beats per minute (bpm) was recorded via echocardiography every 15 min during the procedure. Cohort characteristics, fetal bradycardia and maternal physiologic parameters were compared between the groups.

Results: Fetuses undergoing an open repair more frequently developed bradycardia defined as <110 bpm (32% vs. 3.8%, p = 0.008), and a trend was observed for FHR decreases more than 25 bpm from baseline (20% vs. 3.8%, p = 0.073). Profound bradycardia less than 80 bpm was rare, occurring in only three operations (two in open, one in fetoscopic repair) with two fetuses (one in each group) requiring emergency cesarean delivery.

Conclusion: When compared to open fetal surgery, fetal bradycardia occurred less frequently in fetoscopic surgery despite a significantly greater anesthetic exposure and the use of the intraamniotic carbon dioxide insufflation.

Download full-text PDF

Source
http://dx.doi.org/10.1002/pd.6626DOI Listing

Publication Analysis

Top Keywords

spina bifida
16
fetal bradycardia
12
bradycardia open
8
open versus
8
versus fetoscopic
8
undergoing open
8
repairs performed
8
fetal
5
open
5
fetoscopic
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!