Real-life evaluation of NIV to CPAP switch in patients with chronic respiratory failure. A case control study.

Respir Med Res

Department of Respiratory Diseases and Intensive Care, Reference Center for Adult Rare Pulmonary Diseases, University Hospital of Dijon-Bourgogne, Dijon, France; University of Bourgogne Franche-Comté, Dijon, France; Centre des Sciences du Goût et de l'Alimentation, UMR 6265 CNRS 1234 INRA, University of Bourgogne Franche-Comté, Dijon, France. Electronic address:

Published: November 2024

Background: Non-invasive ventilation (NIV) is a standard of care for hypercapnic chronic respiratory failure (CRF). Obstructive sleep apnea syndrome (OSA) frequently contributes to hypoventilation in CRF patients. CPAP improves hypercapnia in selected COPD and obese patients, like NIV. We aimed to describe the profile of patients switching from NIV to CPAP in a cohort of patients on long-term ventilation and to identify the factors associated with a successful switch.

Methods: In this case-control study, 88 consecutive patients who were candidates for a NIV-CPAP switch were compared with 266 controls among 394 ventilated patients treated at the Dijon University Hospital between 2015 and 2020. They followed a standardized protocol including a poly(somno)graphy recorded after NIV withdrawal for three nights. CPAP trial was performed if severe OSA was confirmed. Patients were checked for recurrent hypoventilation after 1 and 23[14-46] nights under CPAP.

Results: Patients were 53% males, median age 65 [56-74] years, and median BMI 34 [25-38.5] kg/m. Sixty four percent of patients were safely switched and remained on long-term CPAP. In multivariate analysis, the probability of a NIV-CPAP switch was correlated to older age (OR: 1.3 [1.01-1.06]), BMI (OR: 1.7 [1.03-1.12]), CRF etiology (OR for COPD: 20.37 [4.2-98,72], OR for obesity: 7.31 [1.58-33.74]), circumstances of NIV initiation (OR for acute exacerbation: 11.64 [2.03-66.62]), lower pressure support (OR: 0.90 [0.73-0.92]), lower baseline PaCO (OR: 0.85 [0.80-0.91]) and lower compliance (OR: 0.76 [0.64-0.90]). Among 72 patients who went home under CPAP, pressure support level was the only factor associated with the outcome of the NIV-CPAP switch, even ) with a non-linear correlation. Etiology of chronic respiratory failure, age, BMI, baseline PaCO, circumstances of NIV initiation, time under home NIV or NIV compliance were not predictive of the outcome of the NIV-CPAP switch.

Conclusions: A NIV-CPAP switch is possible in real life conditions in stable obese and COPD patients with underlying OSA.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.resmer.2024.101114DOI Listing

Publication Analysis

Top Keywords

niv-cpap switch
16
patients
12
chronic respiratory
12
respiratory failure
12
niv
9
niv cpap
8
patients cpap
8
circumstances niv
8
niv initiation
8
pressure support
8

Similar Publications

Real-life evaluation of NIV to CPAP switch in patients with chronic respiratory failure. A case control study.

Respir Med Res

November 2024

Department of Respiratory Diseases and Intensive Care, Reference Center for Adult Rare Pulmonary Diseases, University Hospital of Dijon-Bourgogne, Dijon, France; University of Bourgogne Franche-Comté, Dijon, France; Centre des Sciences du Goût et de l'Alimentation, UMR 6265 CNRS 1234 INRA, University of Bourgogne Franche-Comté, Dijon, France. Electronic address:

Background: Non-invasive ventilation (NIV) is a standard of care for hypercapnic chronic respiratory failure (CRF). Obstructive sleep apnea syndrome (OSA) frequently contributes to hypoventilation in CRF patients. CPAP improves hypercapnia in selected COPD and obese patients, like NIV.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!