Background: Total elbow arthroplasty (TEA) remains a valuable tool for treating inflammatory, degenerative, and traumatic elbow conditions. This study aimed to understand the incidence of and risk factors for reoperation following TEA at a high-volume center utilizing an implant with a convertible linkage and the potential for anatomic lateral column reconstruction.
Methods: All patients undergoing primary TEA with the Latitude prosthesis (Stryker) from July 2001 to May 2020 were identified. Patient characteristics, the surgical indication, and implant characteristics were obtained. Additionally, the indications and timing were identified for reoperations. Postoperative radiographs were analyzed to assess cement quality, implant position, lateral column reconstruction, and distal humeral bone loss.
Results: Two hundred and nineteen TEAs were performed in 206 patients; 162 (74.0%) were in female patients, the mean patient age was 61 years (range, 23 to 95 years), and the mean follow-up was 11.8 years (range, 2 to 21 years). The most common indication for surgery was sequelae of trauma (36%). Ninety elbows (41.1%) required 200 reoperations at a mean of 19.6 months. Forty TEAs (18.3%) required revision of nonmodular implants, with 14 (6.4%) undergoing definitive explantation. The 5 and 10-year survivorship was 86.1% and 79.7%, respectively. The most common of the reasons for revision was aseptic loosening (53.8%), and the most common cause for non-revision reoperation was infection (23%). Younger age and greater follow-up duration were associated with greater revision and reoperation risks. Aseptic ulnar loosening was associated with a short ulnar stem length and component linkage (30% of short linked ulnar stems loosened; p < 0.001). Aseptic humeral loosening was associated with less-than-adequate cement-mantle quality (p = 0.04).
Conclusions: Extended follow-up of the Latitude prosthesis at a high-volume center demonstrates that TEA continues to be hampered by a high reoperation rate, primarily due to infection and aseptic loosening. Technical factors such as good cement-mantle quality, longer stem length, and unlinked implants may play a role in preventing aseptic loosening. Further work is required to optimize long-term outcomes following TEA through improved understanding of appropriate surgical indications, techniques, and implant utilization.
Level Of Evidence: Therapeutic Level IV . See Instructions for Authors for a complete description of levels of evidence.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.2106/JBJS.23.01171 | DOI Listing |
J Clin Orthop Trauma
January 2025
Loyola University Health System, Department of Orthopaedic Surgery and Rehabilitation, 2160 South First Avenue, 60153, Maywood, IL, USA.
Introduction: Mobile-bearing (MB) inserts, designed to minimize aseptic loosening and to reduce contact stresses leading to polyethylene wear, are an alternative to fixed-bearing (FB) inserts. Most studies have shown no significant difference between MB and FB constructs, and there is limited long-term data comparing the two constructs [1,2,3,4]. The purpose of this study was to report the outcomes of a randomized controlled trial comparing MB versus FB inserts on patients with minimum 20-year follow-up.
View Article and Find Full Text PDFHip Int
January 2025
Department of Orthopaedic Surgery, Hospital de Sant Pau (HSCSP), Barcelona, Spain.
Background: Survival at 25 years' follow-up for total hip arthroplasty (THA) has been reported at 5%-77%, with hydroxyapatite (HA) coating, due to its osteo-conductive properties, used to enhance implant fixation and survival. The progressive increase in life expectancy raises doubts regarding HA-coated THA survival and THA revision surgery risk. The aim of our study was to retrospectively analyse survival for primary uncemented fully HA-coated THA after 28 years' follow-up.
View Article and Find Full Text PDFJ Shoulder Elbow Surg
January 2025
Department of Orthopedic Surgery, Auckland City Hospital, Grafton, Auckland, New Zealand.
Hypothesis And Background: As the incidence of reverse total shoulder arthroplasty (RTSA) continues to rise, better understanding of the long-term risks and complications is necessary to determine the best choice of implant. The majority (75%) of RTSA performed in New Zealand use either SMR (Systema Multiplana Randelli, Lima-LTO, Italy) or Delta Xtend (DePuy Synthes, USA). The aim of this registry-based study was to compare implant survival, risk of revision and reasons for revision between the two most frequently used RTSA prostheses: SMR and Delta Xtend.
View Article and Find Full Text PDFJ Arthroplasty
January 2025
Rush University Medical Center, 1611 W Harrison St, Chicago, IL, 60612.
Background: Revision of a unicompartmental to a total knee arthroplasty (TKA) is often compared to primary TKA with regard to its technical difficulty and complication rates. We sought to compare medical and surgical complications following revision unicompartmental knee arthroplasty (UKA) to those following primary TKA and aseptic revision TKA.
Methods: A national administrative claims database was queried for patients undergoing revision UKA between 2010 and 2019.
J Orthop Surg Res
January 2025
Department of Orthopaedic Surgery, Shanxi Medical University Second Affiliated Hospital, Taiyuan, China.
Objective: This meta-analysis evaluates the comparative efficacy of lateral unicompartmental arthroplasty (UKA) versus medial UKA in treating unicompartmental knee osteoarthritis (KOA).
Methods: We systematically searched Cochrane, PubMed, Embase, and Web of Science databases from January 2000 to September 2024. Literature screening, quality assessment, and data extraction were conducted based on predefined inclusion and exclusion criteria.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!