Ultra-high sensitivity pH sensor based on vertical organic electrochemical transistors with extended gate.

Mikrochim Acta

Key Laboratory of Grain Information Processing and Control, Henan University of Technology, Ministry of Education, Zhengzhou, 450001, China.

Published: June 2024

An ultra-high sensitivity pH sensor based on vertical organic electrochemical transistors (vOECT) with extended gate was proposed. The vOECT, which exhibited high transconductance (g), was for the first time used in the preparation of a pH sensor. The extended gate was modified by electrochemical deposition of polyaniline (PANI) using the cyclic voltammetry (CV) technique. Open circuit potential (OCP) measurements were used to optimize the scan rate, showing a super-Nernstian sensitivity at all scan rates. The pH sensor based on vOECT with extended gate was investigated at different pH levels, and it exhibited an ultra-high sensitivity of 3363.6 µA/pH in the pH range 5-9, which was about 36 times greater than the maximum current sensitivity (91 µA/pH) of other transistor-based pH sensors, to the best of our knowledge. This pH sensor performed excellently in terms of reversibility, long-term stability, and selectivity. To confirm the reliability of the pH sensor, we conducted measurements on real samples using this pH sensor and compared the results with those obtained from a standard pH meter. The ultra-high sensitivity pH sensor based on vOECT with extended gate offers a sensitive and promising alternative in environmental monitoring, food safety, chemistry, clinical diagnostics, and bio-sensing applications.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00604-024-06472-4DOI Listing

Publication Analysis

Top Keywords

extended gate
20
sensor based
16
ultra-high sensitivity
12
sensitivity sensor
12
voect extended
12
sensor
8
based vertical
8
vertical organic
8
organic electrochemical
8
electrochemical transistors
8

Similar Publications

This study presents an innovative glucose detection platform, featuring a highly sensitive, non-enzymatic glucose sensor. The sensor integrates nickel nanowires and a graphene thin film deposited on the gate region of an extended-gate electric double-layer field-effect transistor (EGEDL-FET). This unique combination of materials and device structure enables superior glucose sensing performance.

View Article and Find Full Text PDF

Detection and imaging of dual miRNAs based on AND logic gates can improve the accuracy of the early diagnosis of disease. However, a single target may lead to false positive. Hence, this work rationally integrates hyperbranched rolling circle amplification (HRCA) with Cas12a by replacing the PAM sequence with a bubble to sensitively detect and image miRNA-10b and miRNA-21 based on the AND logic gate.

View Article and Find Full Text PDF

Resting-State EEG Oscillations in Amyotrophic Lateral Sclerosis (ALS): Toward Mechanistic Insights and Clinical Markers.

J Clin Med

January 2025

Faculty of Physical Culture and Health, Institute of Physical Culture Sciences, University of Szczecin, Al. Piastów 40B blok 6, 71-065 Szczecin, Poland.

Amyotrophic lateral sclerosis (ALS) is a complex, progressive neurodegenerative disorder characterized by the degeneration of motor neurons in the brain, brainstem, and spinal cord. Several neuroimaging techniques can help reveal the pathophysiology of ALS. One of these is the electroencephalogram (EEG), a noninvasive and relatively inexpensive tool for examining electrical activity of the brain with excellent temporal precision.

View Article and Find Full Text PDF

Long-Time Coherent Integration (LTCI) utilizes digital integration to combine multiple coherent cycles, thereby improving the signal-to-noise ratio (SNR). Our previous work introduced single-bit LTCI, an approach optimized for FPGA implementation, but faced challenges of output saturation at high SNR levels and inherent limitations in SNR gain (SNRG), which are insufficient for certain applications. This paper presents a threshold tracking method that improves the performance of single-bit LTCI in high-SNR scenarios.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!