Background: Accurate identification of vascular lumen region founded the base of bubble detection and bubble grading, which played a significant role in the detection of vascular gas emboli for the diagnosis of decompression sickness.
Objectives: To assist in the detection of vascular bubbles, it is crucial to develop an automatic algorithm that could identify vascular lumen areas in ultrasound videos with the interference of bubble presence.
Methods: This article proposed an automated vascular lumen region recognition (VLRR) algorithm that could sketch the accurate boundary between vessel lumen and tissues from dynamic 2D ultrasound videos. It adopts 2D ultrasound videos of the lumen area as input and outputs the frames with circled vascular lumen boundary of the videos. Normalized cross-correlation method, distance transform technique, and region growing technique were adopted in this algorithm. Results A double-blind test was carried out to test the recognition accuracy of the algorithm on 180 samples in the images of 6 different grades of bubble videos, during which, intersection over union and pixel accuracy were adopted as evaluation metrics. The average IOU on the images of different bubble grades reached 0.76. The mean PA on 6 of the images of bubble grades reached 0.82.
Conclusion: It is concluded that the proposed method could identify the vascular lumen with high accuracy, potentially applicable to assist clinicians in the measurement of the severity of vascular gas emboli in clinics.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.2174/0115734056298529240531063937 | DOI Listing |
Curr Issues Mol Biol
January 2025
Institute of Experimental Medicine, Almazov National Medical Research Centre, 15B Parkhomenko Street, 194021 Saint Petersburg, Russia.
Myocardial ischemia-reperfusion injury increases myocardial microvascular permeability, leading to enhanced microvascular filtration and interstitial fluid accumulation that is associated with greater microvascular obstruction and inadequate myocardial perfusion. A burst of reactive oxygen species and inflammatory mediators during reperfusion causes myosin light chain kinase (MLCK)-dependent endothelial hyperpermeability, which is considered a preventable cause of reperfusion injury. In the present study, a single intravenous injection of MLCK peptide inhibitor PIK7 (2.
View Article and Find Full Text PDFNMC Case Rep J
December 2024
Department of Neurosurgery, Institute of Science Tokyo, Tokyo, Japan.
Moyamoya disease (MMD) is characterized by distinct histopathological changes in intracranial arteries, such as narrowing of the arterial lumen due to thickening of the tunica intima, waving of the internal elastic membranes, and thinning of the tunica media. Ring finger protein 213 is a susceptibility gene for MMD that affects clinical outcomes. However, little is known about its relationship with histopathology.
View Article and Find Full Text PDFJ Cardiothorac Surg
January 2025
Department of Thyroid Breast Cardiothoracic & Vascular Surgery, Beibei District Hospital of Traditional Chinese Medicine, No. 380 Jiangjun Road, Beibei District, Chongqing, 400700, China.
Background: To evaluate the clinical diagnostic value of third-generation dual-source CT for pulmonary embolism, focusing on the optimization of dual-source CT scanning with dynamic reconstruction in acute pulmonary embolism (PE) and various imaging manifestations.
Methods: Eighty-two patients with pulmonary embolism were enrolled and randomly divided into standard CT angiography (SCTA) and dynamic CT angiography (DCTA). DCTA patients were divided into dynamic CT angiography arterial phase (DCTAa), time phase Angiography reconstruction (TMIP-CTA), and 4D noise reduction TMIP-CTA according to the image reconstruction.
J Cardiothorac Surg
January 2025
The First Department of Cardiology, Beidahuang Industry Group General Hospital, Harbin, 150000, Heilongjiang Province, China.
Objective: it was to evaluate the efficacy and safety of rapamycin-eluting stents at different doses in the treatment of coronary artery narrowing in miniature pigs.
Methods: a total of 20 miniature pigs were randomly assigned into four groups: S1 group (low-dose rapamycin-coated stent, 55 µg/mm), S2 group (medium-dose rapamycin-coated stent, 120 µg/mm), S3 group (high-dose rapamycin-coated stent, 415 µg/mm), and D0 group (bare metal stent). The stent size was 3.
J Vasc Interv Radiol
January 2025
Department of Radiology, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Republic of Korea.
Purpose: To evaluate the efficacy and safety of a novel drug-coated balloon (DCB), Genoss DCB (Genoss) using shellac plus vitamin E as an excipient, compared to a reference DCB using urea.
Materials And Methods: Patients with femoropopliteal arterial disease under Rutherford classes 2-5 were enrolled in this prospective, multicenter, non-inferiority clinical trial, and randomly assigned 1:1 to Genoss DCB and IN.PACT Admiral (Medtronic).
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!