Background: Accurate identification of vascular lumen region founded the base of bubble detection and bubble grading, which played a significant role in the detection of vascular gas emboli for the diagnosis of decompression sickness.

Objectives: To assist in the detection of vascular bubbles, it is crucial to develop an automatic algorithm that could identify vascular lumen areas in ultrasound videos with the interference of bubble presence.

Methods: This article proposed an automated vascular lumen region recognition (VLRR) algorithm that could sketch the accurate boundary between vessel lumen and tissues from dynamic 2D ultrasound videos. It adopts 2D ultrasound videos of the lumen area as input and outputs the frames with circled vascular lumen boundary of the videos. Normalized cross-correlation method, distance transform technique, and region growing technique were adopted in this algorithm. Results A double-blind test was carried out to test the recognition accuracy of the algorithm on 180 samples in the images of 6 different grades of bubble videos, during which, intersection over union and pixel accuracy were adopted as evaluation metrics. The average IOU on the images of different bubble grades reached 0.76. The mean PA on 6 of the images of bubble grades reached 0.82.

Conclusion: It is concluded that the proposed method could identify the vascular lumen with high accuracy, potentially applicable to assist clinicians in the measurement of the severity of vascular gas emboli in clinics.

Download full-text PDF

Source
http://dx.doi.org/10.2174/0115734056298529240531063937DOI Listing

Publication Analysis

Top Keywords

vascular lumen
24
lumen region
12
ultrasound videos
12
vascular
9
lumen
8
bubble detection
8
detection vascular
8
vascular gas
8
gas emboli
8
identify vascular
8

Similar Publications

Myocardial ischemia-reperfusion injury increases myocardial microvascular permeability, leading to enhanced microvascular filtration and interstitial fluid accumulation that is associated with greater microvascular obstruction and inadequate myocardial perfusion. A burst of reactive oxygen species and inflammatory mediators during reperfusion causes myosin light chain kinase (MLCK)-dependent endothelial hyperpermeability, which is considered a preventable cause of reperfusion injury. In the present study, a single intravenous injection of MLCK peptide inhibitor PIK7 (2.

View Article and Find Full Text PDF

Moyamoya disease (MMD) is characterized by distinct histopathological changes in intracranial arteries, such as narrowing of the arterial lumen due to thickening of the tunica intima, waving of the internal elastic membranes, and thinning of the tunica media. Ring finger protein 213 is a susceptibility gene for MMD that affects clinical outcomes. However, little is known about its relationship with histopathology.

View Article and Find Full Text PDF

Clinical application of third-generation dual-source CT-based dynamic imaging reconstruction for pulmonary embolism imaging.

J Cardiothorac Surg

January 2025

Department of Thyroid Breast Cardiothoracic & Vascular Surgery, Beibei District Hospital of Traditional Chinese Medicine, No. 380 Jiangjun Road, Beibei District, Chongqing, 400700, China.

Background: To evaluate the clinical diagnostic value of third-generation dual-source CT for pulmonary embolism, focusing on the optimization of dual-source CT scanning with dynamic reconstruction in acute pulmonary embolism (PE) and various imaging manifestations.

Methods: Eighty-two patients with pulmonary embolism were enrolled and randomly divided into standard CT angiography (SCTA) and dynamic CT angiography (DCTA). DCTA patients were divided into dynamic CT angiography arterial phase (DCTAa), time phase Angiography reconstruction (TMIP-CTA), and 4D noise reduction TMIP-CTA according to the image reconstruction.

View Article and Find Full Text PDF

Objective: it was to evaluate the efficacy and safety of rapamycin-eluting stents at different doses in the treatment of coronary artery narrowing in miniature pigs.

Methods: a total of 20 miniature pigs were randomly assigned into four groups: S1 group (low-dose rapamycin-coated stent, 55 µg/mm), S2 group (medium-dose rapamycin-coated stent, 120 µg/mm), S3 group (high-dose rapamycin-coated stent, 415 µg/mm), and D0 group (bare metal stent). The stent size was 3.

View Article and Find Full Text PDF

Purpose: To evaluate the efficacy and safety of a novel drug-coated balloon (DCB), Genoss DCB (Genoss) using shellac plus vitamin E as an excipient, compared to a reference DCB using urea.

Materials And Methods: Patients with femoropopliteal arterial disease under Rutherford classes 2-5 were enrolled in this prospective, multicenter, non-inferiority clinical trial, and randomly assigned 1:1 to Genoss DCB and IN.PACT Admiral (Medtronic).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!