The vertical scale calibration of an interferometric microscope is important for establishing traceability of surface topography measurements to the International System of Units (SI) unit of length, the meter. Building on the calibration procedure for the amplification coefficient developed by de Groot and Beverage [Proc. SPIE , 952610 (2015)], this paper describes a calibration procedure that yields the response curve for the entire vertical scan motion of a coherent scanning interferometric microscope. The method requires only a flat mirror as an artifact, a narrow band spectral filter, an aperture to reduce the effective numerical aperture, and the ability to raise and lower the microscope head so that the center of the interferogram can be varied within the scan range. The local frequency of the interferogram is determined by fitting sections of the interferogram to a sinusoidal function. The nonlinearity determined from the local frequency data can be used to estimate the uncertainty in uncorrected vertical height measurements. We describe how optical profile data can be corrected for nonlinearity due to dynamic effects in the scan motion and show that the correction improves the reproducibility of step height measurements by at least a factor of three and close to that of the repeatability.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11167681PMC
http://dx.doi.org/10.1088/2051-672x/ad44bbDOI Listing

Publication Analysis

Top Keywords

interferometric microscope
12
vertical scale
8
calibration procedure
8
scan motion
8
local frequency
8
height measurements
8
linearizing vertical
4
scale interferometric
4
microscope
4
microscope step-height
4

Similar Publications

We present a non-interferometric technique for quantitative phase imaging (QPI) that is cost-effective, easily integrated into standard microscopes, and capable of wide-field imaging with noncoherent light. Our method measures the phase gradient through optical differentiation using spatially variable amplitude filters, accommodating a range of transmission functions, including commercially available variable neutral-density filters. This flexibility is made possible by a general relationship we derive.

View Article and Find Full Text PDF

A (target) quantum system is often measured through observations performed on a second (meter) system to which the target is coupled. In the presence of global conservation laws holding on the joint meter-target system, the Wigner-Araki-Yanase theorem and its generalizations predict a lower bound on the measurement's error (Ozawa's bound). While practically negligible for macroscopic meters, it becomes relevant for microscopic ones.

View Article and Find Full Text PDF

Simultaneous visualization of membrane fluidity and morphology defines adhesion signatures of cancer cells.

Proc Natl Acad Sci U S A

December 2024

Department of Applied Physics, Graduate School of Engineering, Osaka University, Suita 565-0871, Japan.

Article Synopsis
  • - We created a new optical microscope that can simultaneously image both the fluidity and structure of cell membranes to understand cell adhesion better.
  • - In tests, we observed how a giant unilamellar vesicle interacts with a glass surface, revealing areas of membrane fluidity and corresponding adhesion sites in both cancerous and non-cancerous cells.
  • - By manipulating cholesterol and unsaturated lipids, we identified distinct adhesion signatures in cancer cells, suggesting that our microscope could help study membrane properties in various cell types beyond just cancer.
View Article and Find Full Text PDF

In situ characterization of the electric field of ultrafast pulses is critical in multiphoton microscopy. Although second harmonic generation-based collinear Frequency-Resolved Optical Gating (FROG) addresses this need, the interferometric measurement is challenged by interferometric drift instability, the required high sampling density of the acquired data, and the inability to directly use the interferometric data with conventional FROG retrieval algorithms. We address these issues by combining low-pass Fourier filtering with active kHz dithering of the interferometric path length difference using a piezo-driven retroreflector.

View Article and Find Full Text PDF

Extreme ultraviolet pulses as generated by high harmonic generation (HHG) are a powerful tool for both time-resolved spectroscopy and coherent diffractive imaging. However, the integration of spectroscopy and microscopy to harness the unique broadband spectra provided by HHG is hardly explored due to the challenge to decouple spectroscopic and microscopic information. Here, we present an interferometric approach to this problem that combines Fourier transform spectroscopy (FTS) with Fourier transform holography (FTH).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!