Sparse-view X-ray CT based on a box-constrained nonlinear weighted anisotropic TV regularization.

Math Biosci Eng

School of Mathematics and Statistics, Shandong Normal University, Jinan 250014, China.

Published: March 2024

Sparse-view computed tomography (CT) is an important way to reduce the negative effect of radiation exposure in medical imaging by skipping some X-ray projections. However, due to violating the Nyquist/Shannon sampling criterion, there are severe streaking artifacts in the reconstructed CT images that could mislead diagnosis. Noting the ill-posedness nature of the corresponding inverse problem in a sparse-view CT, minimizing an energy functional composed by an image fidelity term together with properly chosen regularization terms is widely used to reconstruct a medical meaningful attenuation image. In this paper, we propose a regularization, called the box-constrained nonlinear weighted anisotropic total variation (box-constrained NWATV), and minimize the regularization term accompanying the least square fitting using an alternative direction method of multipliers (ADMM) type method. The proposed method is validated through the Shepp-Logan phantom model, alongisde the actual walnut X-ray projections provided by Finnish Inverse Problems Society and the human lung images. The experimental results show that the reconstruction speed of the proposed method is significantly accelerated compared to the existing $ L_1/L_2 $ regularization method. Precisely, the central processing unit (CPU) time is reduced more than 8 times.

Download full-text PDF

Source
http://dx.doi.org/10.3934/mbe.2024223DOI Listing

Publication Analysis

Top Keywords

box-constrained nonlinear
8
nonlinear weighted
8
weighted anisotropic
8
x-ray projections
8
proposed method
8
regularization
5
method
5
sparse-view x-ray
4
x-ray based
4
based box-constrained
4

Similar Publications

Sparse-view computed tomography (CT) is an important way to reduce the negative effect of radiation exposure in medical imaging by skipping some X-ray projections. However, due to violating the Nyquist/Shannon sampling criterion, there are severe streaking artifacts in the reconstructed CT images that could mislead diagnosis. Noting the ill-posedness nature of the corresponding inverse problem in a sparse-view CT, minimizing an energy functional composed by an image fidelity term together with properly chosen regularization terms is widely used to reconstruct a medical meaningful attenuation image.

View Article and Find Full Text PDF

Surrogate optimisation strategies for intraocular lens formula constant optimisation.

Acta Ophthalmol

September 2024

Dr. Rolf M. Schwiete Center for Limbal Stem Cell and Aniridia Research, Saarland University, Homburg/Saar, Germany.

Purpose: To investigate surrogate optimisation (SO) as a modern, purely data-driven, nonlinear adaptive iterative strategy for lens formula constant optimisation in intraocular lens power calculation.

Methods: A SO algorithm was implemented for optimising the root mean squared formula prediction error (rmsPE, defined as predicted refraction minus achieved refraction) for the SRKT, Hoffer Q, Holladay, Haigis and Castrop formulae in a dataset of N = 888 cataractous eyes with implantation of the Hoya Vivinex hydrophobic acrylic aspheric lens. A Gaussian Process estimator was used as the model, and the SO was initialised with equidistant datapoints within box constraints, and the number of iterations restricted to either 200 (SRKT, Hoffer Q, Holladay) or 700 (Haigis, Castrop).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!