Melody transcatheter pulmonary valve replacement: a single-center case series in Southeast Asia.

BMC Cardiovasc Disord

Division of Pediatric Cardiology, Department of Pediatrics, Faculty of Medicine Ramathibodi Hospital, Mahidol University, 270 Rama 6 Rd, Rachathewi, Bangkok, 10400, Thailand.

Published: June 2024

Background: Studies of transcatheter pulmonary valve replacement (TPVR) with the Melody valve have demonstrated good clinical and hemodynamic outcomes. Our study analyzes the midterm clinical and hemodynamic outcomes for patients who underwent Melody valve implantation in Southeast Asia.

Methods: Patients with circumferential conduits or bioprosthetic valves and experiencing post-operative right ventricular outflow tract (RVOT) dysfunction were recruited for Melody TPVR.

Results: Our cohort (n = 14) was evenly divided between pediatric and adult patients. The median age was 19 years (8-38 years), a male-to-female ratio of 6:1 with a median follow-up period of 48 months (16-79 months), and the smallest patient was an 8-year-old boy weighing 18 kg. All TPVR procedures were uneventful and successful with no immediate mortality or conduit rupture. The primary implant indication was combined stenosis and regurgitation. The average conduit diameter was 21 ± 2.3 mm. Concomitant pre-stenting was done in 71.4% of the patients without Melody valve stent fractures (MSFs). Implanted valve size included 22-mm (64.3%), 20-mm (14.3%), and 18-mm (21.4%). After TPVR, the mean gradient across the RVOT was significantly reduced from 41 mmHg (10-48 mmHg) to 16 mmHg (6-35 mmHg) at discharge, p < 0.01. Late follow-up infective endocarditis (IE) was diagnosed in 2 patients (14.3%). Overall freedom from IE was 86% at 79 months follow-up. Three patients (21.4%) developed progressive RVOT gradients.

Conclusion: For patients in Southeast Asia with RVOT dysfunction, Melody TPVR outcomes are similar to those reported for patients in the US in terms of hemodynamic and clinical improvements. A pre-stenting strategy was adopted and no MSFs were observed. Post-implantation residual stenosis and progressive stenosis of the RVOT require long term monitoring and reintervention. Lastly, IE remained a concern despite vigorous prevention and peri-procedural bacterial endocarditis prophylaxis.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11170848PMC
http://dx.doi.org/10.1186/s12872-024-03919-7DOI Listing

Publication Analysis

Top Keywords

melody valve
12
transcatheter pulmonary
8
pulmonary valve
8
valve replacement
8
clinical hemodynamic
8
hemodynamic outcomes
8
valve
6
melody
5
melody transcatheter
4
replacement single-center
4

Similar Publications

Background: Patients after transcatheter pulmonary valve implantation (TPVI) are at increased risk for infective prosthetic valve endocarditis. Diagnosis of infective endocarditis (IE) following TPVI is particularly difficult due to impaired visualization of the transcatheter pulmonary valve (TPV) with echocardiography [Delgado V, Ajmone Marsan N, de Waha S, Bonaros N, Brida M, Burri H, et al. 2023 ESC guidelines for the management of endocarditis.

View Article and Find Full Text PDF

Background: Patients with congenital heart disease (CHD) often require prosthetic valve implantation, increasing their lifetime risk of developing prosthetic valve endocarditis (PVE). The purpose of this study was to determine the incidence, risk factors, and outcomes of PVE in adults with CHD.

Method: Retrospective cohort study of adults with CHD and prior prosthetic valve implantation (2003-2023).

View Article and Find Full Text PDF

Background: In small children with left atrioventricular valve dysfunction, valve repair is preferred but some will require valve replacement. No prosthetic valve has growth potential, bioprostheses have poor durability, and mechanical prostheses have high rates of thromboembolic and hemorrhagic complications. We reviewed our experience with a modified bovine jugular vein valve designed for use in the right ventricular outflow tract (Melody valve, Medtronic) and compared this with contemporary mechanical valve replacement.

View Article and Find Full Text PDF

Objectives: To describe the workflow and value of three-dimensional rotational angiography (3DRA) in percutaneous pulmonary valve implantation (PPVI).

Background: 3DRA offers visualization of the entire topography in the chest and may enhance safety and reduce the risk for complications in PPVI through improved pre-procedural planning and per-procedural guidance.

Methods: All PPVI procedures with the use of 3DRA performed between August 2011 and December 2022 were reviewed.

View Article and Find Full Text PDF

Background: Infective endocarditis (IE) poses significant risks following percutaneous pulmonary valve implantation (PPVI) or surgical replacement (PVR).

Aims: This study evaluates the effectiveness of emergency percutaneous treatment in stabilizing patients with severe right ventricular dysfunction or obstructive cardiac shock, allowing for delayed surgical or percutaneous valve replacement.

Methods: This retrospective study examines 16 patients (age 19.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!