Event cameras triggered a paradigm shift in the computer vision community delineated by their asynchronous nature, low latency, and high dynamic range. Calibration of event cameras is always essential to account for the sensor intrinsic parameters and for 3D perception. However, conventional image-based calibration techniques are not applicable due to the asynchronous, binary output of the sensor. The current standard for calibrating event cameras relies on either blinking patterns or event-based image reconstruction algorithms. These approaches are difficult to deploy in factory settings and are affected by noise and artifacts degrading the calibration performance. To bridge these limitations, we present E-Calib, a novel, fast, robust, and accurate calibration toolbox for event cameras utilizing the asymmetric circle grid, for its robustness to out-of-focus scenes. E-Calib introduces an efficient reweighted least squares (eRWLS) method for feature extraction of the calibration pattern circles with sub-pixel accuracy and robustness to noise. In addition, a modified hierarchical clustering algorithm is devised to detect the calibration grid apart from the background clutter. The proposed method is tested in a variety of rigorous experiments for different event camera models, on circle grids with different geometric properties, on varying calibration trajectories and speeds, and under challenging illumination conditions. The results show that our approach outperforms the state-of-the-art in detection success rate, reprojection error, and pose estimation accuracy.

Download full-text PDF

Source
http://dx.doi.org/10.1109/TIP.2024.3410673DOI Listing

Publication Analysis

Top Keywords

event cameras
20
fast robust
8
robust accurate
8
calibration
8
accurate calibration
8
calibration toolbox
8
toolbox event
8
event
6
cameras
5
e-calib fast
4

Similar Publications

Background And Purpose: Physical therapists play a vital role in preventing and managing falls in older adults. With advancements in digital health and technology, community fall prevention programs need to adopt valid and reliable telehealth-based assessments. The purpose of this study was to evaluate the validity and reliability of the telehealth-based timed up and go (TUG) test, 30-second chair stand test (30s-CST), and four-stage (4-stage) balance test as functional components of the Stopping Elderly Accidents, Deaths, and Injuries (STEADI) fall risk assessment.

View Article and Find Full Text PDF

Significance: Functional brain imaging experiments in awake animals require meticulous monitoring of animal behavior to screen for spontaneous behavioral events. Although these events occur naturally, they can alter cell signaling and hemodynamic activity in the brain and confound functional brain imaging measurements.

Aim: We developed a centralized, user-friendly, and stand-alone platform that includes an animal fixation frame, compact peripheral sensors, and a portable data acquisition system.

View Article and Find Full Text PDF

Infrared array sensor-based fall detection and activity recognition systems have gained momentum as promising solutions for enhancing healthcare monitoring and safety in various environments. Unlike camera-based systems, which can be privacy-intrusive, IR array sensors offer a non-invasive, reliable approach for fall detection and activity recognition while preserving privacy. This work proposes a novel method to distinguish between normal motion and fall incidents by analyzing thermal patterns captured by infrared array sensors.

View Article and Find Full Text PDF

Visual sensors, including 3D light detection and ranging, neuromorphic dynamic vision sensor, and conventional frame cameras, are increasingly integrated into edge-side intelligent machines. However, their data are heterogeneous, causing complexity in system development. Moreover, conventional digital hardware is constrained by von Neumann bottleneck and the physical limit of transistor scaling.

View Article and Find Full Text PDF

Rare Indocyanine-Induced Anaphylactic Shock During Deep Inferior Epigastric Artery Perforator Breast Reconstruction: A Case Report.

Ann Plast Surg

February 2025

From the Department of Plastic and Reconstructive Surgery, Ewha Womans University College of Medicine, Mokdong Hospital, Seoul, Republic of Korea.

Indocyanine green (ICG) is a water-soluble green substance that is detectable through infrared cameras and emits greenish light. Approved for medical use in the 1950s, ICG has gained prominence as a real-time visualization tool. Widely recognized as a generally safe substance, ICG is applied in diverse fields.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!