A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Determination of Photothermal and EMI Shielding Efficiency of Graphene-Silver Nanoparticle Composites Prepared under Low-Dose Gamma Irradiation. | LitMetric

Silver nanoparticles (Ag NPs) have been produced by low-dose (1-20 kGy) gamma irradiation of silver nitrate in the presence of graphene-based material (graphene oxide or electrochemically exfoliated graphene). The large surface area of those graphene-based materials combined with the presence of oxygen-containing functional groups on the surface provided successful nucleation and growth of Ag nanoparticles, which resulted in a uniformly covered graphene surface. The obtained Ag nanoparticles were spherical with a predominant size distribution of 10-50 nm for graphene oxide and 10-100 nm for electrochemically exfoliated graphene. The photothermal efficiency measurement showed a temperature increase upon exposure to a 532 nm laser for all samples and the highest photothermal efficiency was measured for the graphene oxide/Ag NP sample prepared at 5 kGy. Electromagnetic interference (EMI) shielding efficiency measurements showed poor shielding for the composites prepared with graphene oxide. On the other hand, all composites prepared with electrochemically exfoliated graphene showed EMI shielding to some extent, and the best performance was measured for the samples prepared at 5 and 20 kGy doses.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11173576PMC
http://dx.doi.org/10.3390/nano14110912DOI Listing

Publication Analysis

Top Keywords

emi shielding
12
composites prepared
12
graphene oxide
12
electrochemically exfoliated
12
exfoliated graphene
12
shielding efficiency
8
gamma irradiation
8
irradiation silver
8
graphene
8
photothermal efficiency
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!