Conifer shoots exhibit intricate geometries at an exceptionally detailed spatial scale. Describing the complete structure of a conifer shoot, which contributes to a radiation scattering pattern, has been difficult, and the previous respective components of radiative transfer models for conifer stands were rather coarse. This paper presents a dataset aimed at models and applications requiring detailed 3D representations of needle shoots. The data collection was conducted in the Järvselja RAdiation transfer Model Intercomparison (RAMI) pine stand in Estonia. The dataset includes 3-dimensional surface information on 10 shoots of two conifer species present in the stand (5 shoots per species) - Scots pine ( L.) and Norway spruce ( L. ). The samples were collected on 26th July 2022, and subsequently blue light 3D photogrammetry scanning technique was used to obtain their high-resolution 3D point cloud representations. For each of these samples, the dataset comprises of a photo of the sampled shoot and its obtained 3-dimensional surface reconstruction. Scanned shoots may replace previous, artificially generated models and contribute to the more realistic representation of 3D forest representations and, consequently, more accurate estimates of related parameters and processes by radiative transfer models.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11166687PMC
http://dx.doi.org/10.1016/j.dib.2024.110543DOI Listing

Publication Analysis

Top Keywords

3-dimensional surface
12
scots pine
8
pine norway
8
norway spruce
8
järvselja radiation
8
radiation transfer
8
transfer model
8
model intercomparison
8
intercomparison rami
8
rami pine
8

Similar Publications

Craniosynostosis, a condition marked by the premature fusion of one or more cranial sutures, exhibits diverse phenotypes. This study aims to advance the understanding of these phenotypes beyond the conventional 2-dimensional analysis by focusing on identifying indicators of increased intracranial pressure (ICP) such as bony thinning or irregularities in skull morphology. A retrospective review was conducted for all pediatric patients with midline craniosynostosis who presented to our tertiary academic center for evaluation.

View Article and Find Full Text PDF

Superficial lesions of the face are often treated with an electron beam and surface collimation utilizing a conformal lead shield with an opening around the region of treatment (ROT). To fabricate the lead shield, an imprint of the patient face is needed. Historically, this was achieved using a laborious and time-consuming process that involved a gypsum imprinted model (GIM) of the patient topography.

View Article and Find Full Text PDF

The Accuracy of Cardiac Surface Conduction Velocity Measurements.

JACC Clin Electrophysiol

December 2024

The Hull Family Cardiac Fibrillation Management Laboratory, Toronto General Hospital, University Health Network, Toronto, Ontario, Canada.

Background: Conduction velocity (CV) is a measure of the health of myocardial tissue. It can be measured by taking differences in local activation times from intracardiac electrodes. Several factors introduce error into the measurement, among which ignoring the 3-dimensional aspect is a major detriment.

View Article and Find Full Text PDF

As the demand for clean water intensifies, developing effective methods for removing pollutants from contaminated sources becomes increasingly crucial. This work establishes a method for additive manufacturing of functional polymer sorbents with hollow porous features, designed to enhance interactions with organic micropollutants. Specifically, core-shell filaments are used as the starting materials, which contain polypropylene (PP) as the shell and poly(acrylonitrile-co-butadiene-co-styrene) as the core, to fabricate 3-dimensional (3D) structures on-demand via material extrusion.

View Article and Find Full Text PDF

Background: Studies have revealed abnormalities of the epiphyseal plate of the distal femur in patients with trochlear dysplasia, but it is unclear whether the epiphyseal plate could be remodeled after surgical correction of patellar dislocation.

Purpose: To investigate whether the morphology of the epiphyseal plate and trochlea could be improved after medial patellar retinaculum plasty in skeletally immature patients and to investigate the correlations between the morphology of the epiphyseal plate and trochlear dysplasia as well as clinical outcomes.

Study Design: Cohort study; Level of evidence, 3.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!