A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Clinical and Radiographic Status and PISF Levels of PGE2 Around Cement and Screw Retained Implants. | LitMetric

Background: The aim was to assess the peri-implant clinicoradiographic status and prostaglandin E2 (PGE2) levels in peri-implant sulcular fluid (PISF) samples collected from individuals with cement-retained and crew-retained implants.

Methods: In this observational study, participants with cement-retained and screw-retained implants were enrolled. A questionnaire was utilized to gather demographic information and assess the educational background of the participants. Peri-implant modified plaque and bleeding indices, probing depth, and crestal bone loss were measured. Subsequently, PISF samples were collected, and corresponding volumes were recorded. Commercial kits employing enzyme-linked immunosorbent assay were employed to quantify PGE2 levels. The sample size was determined, and group comparisons were conducted using the Student t test and the Mann-Whitney U-test. Logistic regression models were constructed to evaluate the correlation between PGE2 levels and clinicoradiographic and demographics. The predefined level of significance was established at P < .05.

Results: Sixty-seven participants, consisting of 33 with cement-retained implants and 34 with screw-retained implants, were included in the study. The mean ages for individuals with cement and screw-retained implants were 54.2 ± 8.7 and 58.7 ± 7.4 years, respectively. The majority of participants had completed university-level education. Reportedly, 87.9% and 82.4% of individuals with cement and screw-retained implants, respectively brushed teeth twice daily. No significant differences were observed in clinicoradiographic parameters, PGE2 volume, and levels between cement-retained and screw-retained implants. There was no correlation between PGE2 levels and peri-implant clinicoradiographic parameters among individuals with either cement-retained or screw-retained implants.

Conclusions: Cement-retained and screw-retained implants exhibit a consistent peri-implant clinicoradiographic status, accompanied by stable levels of PGE2 in PISF provided oral hygiene maintenance regimens are stringently followed.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11551583PMC
http://dx.doi.org/10.1016/j.identj.2024.04.026DOI Listing

Publication Analysis

Top Keywords

screw-retained implants
24
pge2 levels
16
cement-retained screw-retained
16
peri-implant clinicoradiographic
12
levels pge2
8
implants
8
clinicoradiographic status
8
levels peri-implant
8
pisf samples
8
samples collected
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!