Objective: Evaluate the effects of five disinfection methods on bacterial concentrations in hospital sink drains, focusing on three opportunistic pathogens (OPs): Serratia marcescens, Pseudomonas aeruginosa and Stenotrophomonas maltophilia.
Design: Over two years, three sampling campaigns were conducted in a neonatal intensive care unit (NICU). Samples from 19 sink drains were taken at three time points: before, during, and after disinfection. Bacterial concentration was measured using culture-based and flow cytometry methods. High-throughput short sequence typing was performed to identify the three OPs and assess S. marcescens persistence after disinfection at the genotypic level.
Setting: This study was conducted in a pediatric hospitals NICU in Montréal, Canada, which is divided in an intensive and intermediate care side, with individual rooms equipped with a sink.
Interventions: Five treatments were compared: self-disinfecting drains, chlorine disinfection, boiling water disinfection, hot tap water flushing, and steam disinfection.
Results: This study highlights significant differences in the effectiveness of disinfection methods. Chlorine treatment proved ineffective in reducing bacterial concentration, including the three OPs. In contrast, all other drain interventions resulted in an immediate reduction in culturable bacteria (4-8 log) and intact cells (2-3 log). Thermal methods, particularly boiling water and steam treatments, exhibited superior effectiveness in reducing bacterial loads, including OPs. However, in drains with well-established bacterial biofilms, clonal strains of S. marcescens recolonized the drains after heat treatments.
Conclusions: Our study supports thermal disinfection (>80°C) for pathogen reduction in drains but highlights the need for additional trials and the implementation of specific measures to limit biofilm formation.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11168660 | PMC |
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0304378 | PLOS |
Antibiotics (Basel)
December 2024
Faculty of Life Sciences, Rhine-Waal University of Applied Sciences, Marie-Curie-Straße 1, 47533 Kleve, Germany.
. As biofilms are known to harbour (multi-)resistant species, their presence in health settings must be considered critical. Although there is evidence that bacteria spread from drains to the outside, there is still a lack of research data focusing on drain biofilms from hospitals.
View Article and Find Full Text PDFBMC Infect Dis
December 2024
Centre for Infectious Disease Control (CIb), National Institute for Public Health and the Environment (RIVM), Bilthoven, The Netherlands.
We studied nosocomial transmission of multidrug-resistant bla-containing Klebsiella pneumoniae ST147 in a Dutch pediatric oncology center. Whole-genome multilocus sequence typing revealed two genetic clusters consisting of 2 and 5 K. pneumoniae isolates, both from Ukrainian medical evacuees and Dutch patients.
View Article and Find Full Text PDFFront Microbiol
November 2024
State Key Laboratory of Soil and Sustainable Agriculture, Institute of Soil Science, Chinese Academy of Sciences, Nanjing, Jiangsu, China.
J Environ Manage
December 2024
National Sedimentation Laboratory, USDA-Agricultural Research Service, MS, USA.
Conservation practices have been recognized as an important mitigation tool to reduce soil loss and sediment transport from agricultural fields. Multiple conservation structures and farming practices have been proposed to target erosional processes with varying results of sediment trapping efficiency. The quantification of their performance at the watershed scale when multiple integrated and spatiotemporal varying processes occur, remains a challenge.
View Article and Find Full Text PDFJ Hosp Infect
January 2025
Department of Microbiology, Virology and Infection Control, Great Ormond Street Hospital London, UK. Electronic address:
Background: Multi-resistant Gram-negative bacteria (GNB) survive in hospital drains in traps that contain water and may ascend into the sink because of splashes, or biofilm growth.
Aim: To investigate whether the 'Tuba Drain' (TD) a long, bent, continually descending copper tube between the sink outlet and the trap prevents the ascent of bacteria.
Methods: After initial laboratory tests confirmed that the TD prevented bacteria in the U-bend from splashing upwards into the sink outlet, TDs were assessed in a randomized, blinded trial in a hospital outpatient department built in 2019.