In proton pencil beam scanning (PBS) continuous delivery, the beam is continuously delivered without interruptions between spots. For synchrotron-based systems, the extracted beam current exhibits a spill structure, and recent publications on beam current measurements have demonstrated significant fluctuations around the nominal values. These fluctuations potentially lead to dose deviations from those calculated assuming a stable beam current. This study investigated the dosimetric implications of such beam current fluctuations during proton PBS continuous scanning.Using representative clinical proton PBS plans, we performed simulations to mimic a worst-case clinical delivery environment with beam current varies from 50% to 250% of the nominal values. The simulations used the beam delivery parameters optimized for the best beam delivery efficiency of the upcoming particle therapy system at Mayo Clinic Florida. We reconstructed the simulated delivered dose distributions and evaluated the dosimetric impact of beam current fluctuations.Despite significant beam current fluctuations resulting in deviations at each spot level, the overall dose distributions were nearly identical to those assuming a stable beam current. The 1 mm/1% Gamma passing rate was 100% for all plans. Less than 0.2% root mean square error was observed in the planning target volume dose-volume histogram. Minimal differences were observed in all dosimetric evaluation metrics.Our findings demonstrate that with our beam delivery system and clinical planning practice, while significant beam current fluctuations may result in large local move monitor unit deviations at each spot level, the overall impact on the dose distribution is minimal.

Download full-text PDF

Source
http://dx.doi.org/10.1088/1361-6560/ad56f6DOI Listing

Publication Analysis

Top Keywords

beam current
40
current fluctuations
16
beam
15
proton pbs
12
pbs continuous
12
beam delivery
12
current
10
nominal values
8
assuming stable
8
stable beam
8

Similar Publications

Accelerator neutron sources for BNCT: Current status and some pointers for future development.

Appl Radiat Isot

January 2025

Particle Radiation Oncology Research Center, Institute for Integrated Radiation and Nuclear Science, Kyoto University, 2-Asashiro-Nishi, Kumatori-cho, Sennan-gun, Osaka, 590-0494, Japan.

Recent decades have seen the development of accelerator neutron sources suitable for installation in a hospital setting. Numerous challenges have been faced and solved to deliver technology which continues to transform the field of BNCT. This paper begins by briefly reviewing the technologies which are currently, or soon will be, in clinical use.

View Article and Find Full Text PDF

Influence of Photoemission Geometry on Timing and Efficiency in 4D Ultrafast Electron Microscopy.

Chemphyschem

January 2025

University of Minnesota Twin Cities, Chemical Engineering and Materials Science, 421 Washington Avenue SE, 55455, Minneapolis, UNITED STATES OF AMERICA.

Broader adoption of 4D ultrafast electron microscopy (UEM) for the study of chemical, materials, and quantum systems is being driven by development of new instruments as well as continuous improvement and characterization of existing technologies. Perhaps owing to the still-high barrier to entry, the full range of capabilities of laser-driven 4D UEM instruments has yet to be established, particularly when operated at extremely low beam currents (~fA). Accordingly, with an eye on beam stability, we have conducted particle tracing simulations of unconventional off-axis photoemission geometries in a UEM equipped with a thermionic-emission gun.

View Article and Find Full Text PDF

The challenge of imaging low-density objects in an electron microscope without causing beam damage is significant in modern transmission electron microscopy. This is especially true for life science imaging, where the sample, rather than the instrument, still determines the resolution limit. Here, we explore whether we have to accept this or can progress further in this area.

View Article and Find Full Text PDF

This study compared the apical transportation and centering ratio of ProTaper Next (PTN) and XP-endo Shaper (XPS) nickel titanium (NiTi) rotary files in curved root canals using cone beam computed tomography (CBCT). The current in vitro study involved the mesiobuccal canals of mesial roots in 44 extracted mandibular first molars that exhibited apical curvature ranging from 10° to 30°. Two experimental groups were randomly formed from the teeth ( = 22) and subjected to instrumentation with PTN and XPS.

View Article and Find Full Text PDF

Proton therapy of lung cancer patients - Treatment strategies and clinical experience from a medical physicist's perspective.

Phys Med

January 2025

Department of Radiation Oncology (Maastro), GROW School for Oncology and Reproduction, Maastricht University Medical Centre+, Maastricht, the Netherlands. Electronic address:

Purpose: Proton therapy of moving targets is considered a challenge. At Maastro, we started treating lung cancer patients with proton therapy in October 2019. In this work, we summarise the developed treatment strategies and gained clinical experience from a physics point of view.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!