A cross-sectional study was conducted among 126 preschool children aged 4-6 years in traffic, industrial, and suburban areas of Penang, Malaysia, to determine their exposure to indoor air pollutants and their associations with respiratory symptoms. A standardised and validated questionnaire was used to collect data on respiratory health symptoms among respondents. An indoor air quality assessment was conducted in selected preschools that included temperature, relative humidity, air velocity, volatile organic compounds (VOCs), and particulate matter (PM, and PM). There were significant differences in median concentrations of PM, PM and relative humidity among study groups. Statistical analysis showed significant associations between air pollutants in preschool with respiratory symptoms. Factors that influenced the increased likelihood of cough and phlegm were linked to the increase in PM exposure. This study suggests regular classroom cleaning and routine maintenance of air conditioners to be done inside the preschools.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1080/09603123.2024.2365308 | DOI Listing |
JAMA Netw Open
January 2025
Department of Obstetrics and Gynecology, Vagelos College of Physicians and Surgeons, Columbia University Irving Medical Center, New York, New York.
Importance: Understanding environmental risk factors for gestational diabetes (GD) is crucial for developing preventive strategies and improving pregnancy outcomes.
Objective: To examine the association of county-level radon exposure with GD risk in pregnant individuals.
Design, Setting, And Participants: This multicenter, population-based cohort study used data from the Nulliparous Pregnancy Outcomes Study: Monitoring Mothers-to-Be (nuMoM2b) cohort, which recruited nulliparous pregnant participants from 8 US clinical centers between October 2010 and September 2013.
Alzheimers Dement
December 2024
UNIVERSITY OF CALIFORNIA, BERKELEY, California, CA, USA; Department of Psychiatry, SRIHER, Chennai, India.
Background: Exposure to the household air pollution (HAPIN) is a leading health risk in populations in LMIC s and accounts for an estimated 2.3 million premature deaths annually and 91.5 million disability-adjusted life years (Bennitt et al,2021).
View Article and Find Full Text PDFEnviron Sci Process Impacts
January 2025
Department of Civil, Architectural, and Environmental Engineering, Illinois Institute of Technology, Alumni Memorial Hall Room 228, 3201 South Dearborn Street, Chicago, IL 60616, USA.
There is an increasing number of randomized clinical trials intended to assess the effectiveness of indoor air cleaners for improving participant outcomes in real-world settings. In this communication, we synthesize the current state of registered air cleaner intervention trials and call attention to the critical importance of conducting measurements to characterize the performance and utilization of air cleaners in such trials to improve interpretation of exposure measurements and patient outcomes. We draw upon the existing literature and preliminary findings from our ongoing one-year, randomized, single-blind, placebo-controlled case-control trial of stand-alone air filtration in the homes of U.
View Article and Find Full Text PDFACS EST Air
September 2024
Office of the Director, Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Morgantown, West Virginia 26505, United States.
During use of sodium hypochlorite bleach, gas-phase hypochlorous acid (HOCl) and chlorine (Cl) are released, which can react with organic compounds present in indoor air. Reactivity between HOCl/Cl and limonene, a common constituent of indoor air, has been observed. The purpose of this study was to characterize the chemical species generated from gas-phase reactions between HOCl/Cl and limonene.
View Article and Find Full Text PDFPLOS Glob Public Health
January 2025
Royal Danish Academy - Architecture, Design, Conservation, Copenhagen, Denmark.
Improved cooking stoves (ICS) are intended to reduce indoor air pollution and the inefficient use of fuel yet there is often reticence to shift permanently to ICS. Drawing on a scoping review, this article aims to provide a comprehensive overview of factors affecting the acceptability of ICS. A scoping review was carried out using a systematic search strategy of literature.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!