Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Laser-induced filaments have been shown to reduce the voltage necessary to initiate electrical discharges in atmospheric air and guide their propagation over long distances. Here we demonstrate the stable generation of laser filament-guided electrical discharge columns in air initiated by high energy (up to 250 mJ) 1030 nm wavelength laser pulses of 7 ps duration at repetition rates up to 1 kHz and we discuss the processes leading to breakdown. A current proportional to the laser pulse energy is observed to arise as soon as the laser pulse arrives, initiating a high impedance phase of the discharge. Full breakdown, characterized by impedance collapse, occurs 100 ns to several µs later. A record 4.7-fold reduction in breakdown voltage for dc-biased discharges, which remains practically independent of the repetition rate up to 1 kHz, is observed to be primarily caused by a single laser pulse that produces a large (∼80%) density depression. The radial gaps between the filamentary plasma channel and the hollowed electrodes employed are shown to play a significant role in the breakdown dynamics. A rapid increase of 3-4 orders of magnitude in current is observed to follow the formation of localized radial current channels linking the filament to the electrodes. The increased understanding and control of kHz repetition rate filament-guided discharges can aid their use in applications.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1364/OE.506547 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!