Presently most noninvasive methods for assessing extracranial carotid disease have relied on hemodynamic change associated with significant stenosis. Recent evidence has suggested that both ulceration and/or plaque hemorrhage may frequently play an important role in the pathophysiology of carotid disease. To assess the ability of B-mode ultrasound to provide this anatomic information, in a prospective blinded manner we compared B-mode ultrasound and selective four-vessel arteriography to pathologic specimens obtained at the time of 89 carotid endarterectomies. The presence of ulceration, plaque characteristics (particularly hemorrhage), and luminal diameter were described for each modality. While arteriography detected only 16 of 27 ulcerations (sensitivity, 59%), B-mode ultrasound had a greater sensitivity (24/27, 89%). Both modalities had comparable specificities (arteriography, 73%; B-mode ultrasound, 87%). Moreover, B-mode ultrasound was highly sensitive for demonstrating plaque hemorrhage (27/29, 93%), as well as being quite specific (84%). Assessment of luminal reduction by B-mode ultrasound improved with technologist/interpreter experience and was significantly improved by adding real-time spectral analysis. Because of B-mode ultrasound's sensitivity for imaging ulceration and plaque hemorrhage, it offers significant advantages for the noninvasive detection of extracranial carotid disease.

Download full-text PDF

Source
http://dx.doi.org/10.1001/archsurg.1985.01390280037009DOI Listing

Publication Analysis

Top Keywords

b-mode ultrasound
28
carotid disease
12
plaque hemorrhage
12
arteriography pathologic
8
extracranial carotid
8
ulceration plaque
8
ultrasound
7
b-mode
7
carotid
5
correlation b-mode
4

Similar Publications

Objectives: To determine the efficacy of quantitative shear wave elastography in differentiating benign and malignant axillary lymph nodes (ALN).

Methods: Exactly 127 lymph nodes from 127 patients with clinically palpable axillary swelling were examined by both B-mode sonography and elastography from November 2022 to March 2024. Gray-scale sonograms were evaluated based on: the short-axis diameter, shape, hilum, maximum cortical thickness, and border of the ALN.

View Article and Find Full Text PDF

Background: Diaphragm thickness is a potential marker of sarcopenia in addition to muscle mass and strength at extremities. We aimed to clarify the descriptive epidemiology and prognostic significance of diaphragm thickness in the general population.

Methods: The study participants were 3324 community residents (mean age: 61.

View Article and Find Full Text PDF

Regional Image Quality Scoring for 2-D Echocardiography Using Deep Learning.

Ultrasound Med Biol

January 2025

Department of Circulation and Medical Imaging, Norwegian University of Science and Technology - NTNU, Trondheim, Norway; Health Research, SINTEF, Trondheim, Norway.

Objective: To develop and compare methods to automatically estimate regional ultrasound image quality for echocardiography separate from view correctness.

Methods: Three methods for estimating image quality were developed: (i) classic pixel-based metric: the generalized contrast-to-noise ratio (gCNR), computed on myocardial segments (region of interest) and left ventricle lumen (background), extracted by a U-Net segmentation model; (ii) local image coherence: the average local coherence as predicted by a U-Net model that predicts image coherence from B-mode ultrasound images at the pixel level; (iii) deep convolutional network: an end-to-end deep-learning model that predicts the quality of each region in the image directly. These methods were evaluated against manual regional quality annotations provided by three experienced cardiologists.

View Article and Find Full Text PDF

The interrelationship of thyroid volume and function with features of cardiovascular dysfunction has already been investigated but some aspects remain unclear, especially in terms of subclinical cardiovascular dysfunction in euthyroid patients. Intima-media thickness (IMT) measurement in ultrasound B-mode imaging in different vascular beds (most frequently within the common carotid artery) is one of the most important tools for the detection of subclinical atherosclerosis in both clinical practice and research. This article aimed to present the results of our research on the association between the thyroid evaluation parameters and the IMT measured in both the carotid and femoral arteries in euthyroid patients aged 18 to 65 years taking into account the influence of diabetes, hypertension, and excess body mass.

View Article and Find Full Text PDF

Intraoperative ultrasound (ioUS) provides real-time imaging during neurosurgical procedures, with advantages such as portability and cost-effectiveness. Accurate tumor segmentation has the potential to substantially enhance the interpretability of ioUS images; however, its implementation is limited by persistent challenges, including noise, artifacts, and anatomical variability. This study aims to develop a convolutional neural network (CNN) model for glioma segmentation in ioUS images via a multicenter dataset.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!